Request Sense Command
190
T10000: Interface Reference Manual • January 2011
• E20425-01
Sense Data
Table 146. Sense Data Format
Byte
Bit
7
6
5
4
3
2
1
0
0
Valid
Response Code (70h or 71h)
1
Reserved
2
Filemark
EOM
ILI
RSVD
Sense Key
3
thru
6
(MSB)
Information
(LSB)
7
Additional Sense Length (n–7)
8
thru
11
(MSB)
Command Specific Information
(LSB)
12
Additional Sense Code
13
Additional Sense Code Qualifier
14
Field Replaceable Unit Code
15
SKSV
(MSB)
16
Sense Key Specific
17
(LSB)
18
thru
23
(MSB)
Fault Symptom Codes 1–3
(LSB)
24
Tape Type
DAvail
MIRBad
Volsafe
TapeEOL
25
Reserved
LibAtt
RSVD
Parameter
Value
Valid
0 = Information field does not contain valid data
1 = Information field contains valid data
Response Code
70h = Current error, sense data is for the command that
received the check condition
71h = Deferred error, sense data is for a previously issued
command. The current command that received check
condition was not executed.
Filemark
0 = Normal
1 = A Read or Space command encountered a filemark
Содержание Storage Tek T10000
Страница 14: ...Tables xiv T10000 Interface Reference Manual January 2011 E20425 01...
Страница 18: ...What s New xx T10000 Interface Reference Manual January 2011 E20425 01...
Страница 30: ...Considerations 12 T10000 Interface Reference Manual January 2011 E20425 01 Figure 5 Cascading Hubs...
Страница 82: ...Private Loop SCSI Target Discovery 64 T10000 Interface Reference Manual January 2011 E20425 01...
Страница 286: ...Glossary 268 T10000 Interface Reference Manual January 2011 E20425 01...