Mode Select Command
106
T10000: Interface Reference Manual • January 2011
• E20425-01
Mode Select data consists of a header, an optional block descriptor, and
optional page formatted data:
Parameter
Value
PF:
Page Format
0 = Vendor specific format (same as PF = 1)
1 = Page formatted data follows block descriptor, or header
SP:
Save Parameters
0 = Not supported
Parameter List Length
Contains the total number of bytes in the header, block
descriptor, and all pages.
If this length is 0, no mode select data is sent and the
command is ignored.
If this length results in the truncation of the header, block
descriptor, or any page, the command is rejected.
Mode select data can be sent as:
•
Header only
•
Header and page formatted data
•
Header and block descriptor
•
Header, block descriptor, and page formatted data
Pages can be sent in any order. If any page formatted data is
sent, the PF bit is set in the command.