Chapter 3
Software Installation
3-9
The NIU (Network Interface Unit) driver configuration file,
nxge.conf
, might need
to be modified to employ the proper port configurations. The
nxge.conf
file is
located in the
/platform/sun4v/kernel/drv
directory. The following examples
show the proper entries for each switch configuration. These entries are additional to
any other configuration parameters set in the
nxge.conf
file.
Example 1: If Sun Netra CP3240 10-GbE switches are used in Slot 7 and Slot 8, the
nxge.conf
file should have the following entries:
Example 2: If Sun Netra CP3140 1-GbE switches are used in Slot 7 and Slot 8, the
nxge.conf
file should have the following entries:
Example 3: If a Sun Netra CP3140 1-GbE switch is used in Slot 7 and a Sun Netra
CP3240 10-GbE switch in Slot 8, the
nxge.conf
file should have the following
entries:
Example 4: If a Sun Netra CP3240 10-GbE switch is used in Slot 7 and a Sun Netra
CP3140 1-GbE switch is used in Slot 8, the
nxge.conf
file should have the
following entries:
3.6
Downloading and Installing SunVTS
Software
Sun Validation Test Suite (SunVTS™) software is a comprehensive suite that tests
and validates the Sun Netra CP3260 blade server by verifying the configuration and
function of most hardware controllers and devices on the blade server.
name = "SUNW,niusl" parent = "/niu@80" unit-address = "0" phy-type = "xgsd";
name = "SUNW,niusl" parent = "/niu@80" unit-address = "1" phy-type = "xgsd";
name = "SUNW,niusl" parent = "/niu@80" unit-address = "0" phy-type = "gsd";
name = "SUNW,niusl" parent = "/niu@80" unit-address = "1" phy-type = "gsd";
name = "SUNW,niusl" parent = "/niu@80" unit-address = "0" phy-type = "gsd";
name = "SUNW,niusl" parent = "/niu@80" unit-address = "1" phy-type = "xgsd";
name = "SUNW,niusl" parent = "/niu@80" unit-address = "0" phy-type = "xgsd";
name = "SUNW,niusl" parent = "/niu@80" unit-address = "1" phy-type = "gsd";
Содержание Sun Netra CP3260
Страница 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Страница 22: ...1 4 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 1 1 Netra CP3260 Blade Server Front Panel...
Страница 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Страница 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Страница 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Страница 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Страница 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Страница 43: ...Chapter 2 Hardware Installation 2 7...
Страница 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Страница 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Страница 53: ...Chapter 2 Hardware Installation 2 17...
Страница 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Страница 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Страница 105: ...Chapter 5 Hardware Functional Descriptions 5 5 FIGURE 5 2 UltraSPARC T2 Multicore Processor Block Diagram...
Страница 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Страница 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...