5-8
Netra CP3260 Blade Server User’s Guide • April 2009
5.2.1.2
Cores
The UltraSPARC T2 processor provides 8 physical SPARC processor cores and each
physical core is capable of supporting 8 threads for a total of 64 threads.
5.2.1.3
L2 Cache
The UltraSPARC T2 provides a total of 4 Mbytes of L2 cache banked 8 ways.
5.2.1.4
Memory Controller
The UltraSPARC T2 supports 4 FB-DIMM memory controllers, each controller
capable of supporting 2 FB-DIMM memory channels. The UltraSPARC T2 connects
directly to 8 DIMMS (one DIMM per channel) providing for a total of 8 DIMM slots.
See
Section 5.2.2, “Memory Subsystem” on page 5-9
for details on the Netra CP3260
memory design.
5.2.1.5
I/O Interface
The UltraSPARC T2 provides the following I/O interfaces
■
x8 PCI Express interface
■
Two 10 Gbps Ethernet (XAUI) ports
PCI Express
The UltraSPARC T2 provides a PCI Express Unit (PEU) that implements the root
complex behavior of the PCI -Express Base specification 1.0A.
The PEU supports x1, x2, x4, and x8 configuration at the data rate of 2.5Bb/s in each
direction. The PEU also supports the lane reversal feature thus easing blade server
routing restrictions.
XAUI Interface
The XAUI interface is a high speed point-to-point serial interface with four
differential pairs for transmit (TX) and four differential pairs for receive (RX),
operating at 3.125 Gbps.
Содержание Sun Netra CP3260
Страница 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Страница 22: ...1 4 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 1 1 Netra CP3260 Blade Server Front Panel...
Страница 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Страница 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Страница 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Страница 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Страница 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Страница 43: ...Chapter 2 Hardware Installation 2 7...
Страница 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Страница 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Страница 53: ...Chapter 2 Hardware Installation 2 17...
Страница 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Страница 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Страница 105: ...Chapter 5 Hardware Functional Descriptions 5 5 FIGURE 5 2 UltraSPARC T2 Multicore Processor Block Diagram...
Страница 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Страница 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...