Chassis Dimension and Weight
U.S.
Metric
Height
1.73 in (1 rack unit—1U)
4.4 cm
Width 17.16
in.
43.6
cm
Depth (with front bezel)
18.6 in.
47.2 cm
Weight (without drives)
13 lbs
5.9 kg
Weight (fully loaded)
19.4 lbs
8.8 kg
Shipping Weight (product and
packing)
20 lbs
9.5 kg
Environment
The Sun StorEdge S1 array is designed to meet the following requirements:
Environmental Specifications
Climate Control
Location
Minimum to Maximum Range
Temperature (dry bulb)
Operating
5°C to 40°C (41°F to 104°F)
Storage
–25°C to 65°C (–13°F to 149°F)
Transit
–25°C to 65°C (–13°F to 149°F)
Short term (96 consecutive hrs)
Operating
–5°C to 55°C (23°F to 131°F)
Non−operating
–40°C to 70°C (–40°F to 158°F)
Temperature derating (max)
Operating
3.3°C per 1000m (1.7°F per 1000 ft)
above sea level
Relative humidity (non−
condensing)
Operating
5% to 85%
Short term (96 consecutive hrs)
Storage
5% to 95%
Transit
5% to 95%
Operating
5% to 90%
Non−operating
5% to 95%
Altitude (based on drives)
Operating
0m to 3,000m (0 ft to 10,000 ft)
above sea level
Storage
0m to 12,000m (0 ft to 40,000 ft)
above sea level
Transit
0m to 12,000m (0 ft to 40,000 ft)
above sea level
Heat dissipation (maximum)
Operating
150 watts, 512 BTU per hour
Sound power
Operating
6.0B, in accordance with ISO 9296
Idle
6.0B, in accordance with ISO 9296
Earthquake
Location
NEBS requirements for earthquake
Zone 4
Sun StorEdge S1 Array
15
Just the Facts 9/27/01