**ADIC / Sun Confidential**
Sun_StorEdge_L7_Decision_Tree_Rev01_
6.0 NVM SELECT
This error message indicates an NVRAM selection failure. Troubleshooting should begin with cycling power
to the autoloader.
Note:
When powering off the autoloader, the POWER button on the front panel of the autoloader must be
pressed and held for 2 seconds.
DP1:
Check to see if the error message is still present after cycling autoloader power.
R1:
Error message is still present.
A1:
Replace the autoloader.
R1:
Error message no longer present.
A1:
Continue normal autoloader operation.
7.0 NVM WRITE
This error message indicates an NVRAM write failure. Troubleshooting should begin with cycling power to
the autoloader.
Note:
When powering off the autoloader, the POWER button on the front panel of the autoloader must be
pressed and held for 2 seconds.
DP1:
Check to see if the error message is still present after cycling autoloader power.
R1:
Error message is still present.
A1:
Replace the autoloader.
R1:
Error message no longer present.
A1:
Continue normal autoloader operation.
8.0 CAM LIMIT
This error message indicates a cam limit has been reached without tripping a sensor. Troubleshooting
should begin with cycling power to the autoloader.
Note:
When powering off the autoloader, the POWER button on the front panel of the autoloader must be
pressed and held for 2 seconds.
DP1:
Check to see if the error message is still present after cycling autoloader power.
R1:
Error message is still present.
A1:
Replace the autoloader.
R1:
Error message no longer present.
A1:
Continue normal autoloader operation.
9.0 JAW SENSOR
This error message indicates a jaw sensor has been tripped. Troubleshooting should begin with cycling
power to the autoloader.
Note:
When powering off the autoloader, the POWER button on the front panel of the autoloader must be
pressed and held for 2 seconds.
DP1:
Check to see if the error message is still present after cycling autoloader power.
R1:
Error message is still present.
A1:
Replace the autoloader.
R1:
Error message no longer present.
A1:
Continue normal autoloader operation.