Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
restoret3config
•
$LUN
configuration failed to
restore.
• The force option tried
unsuccessfully to reinitialize.
1. Check the Sun StorEdge T3+
configuration with the
showt3
-n t3_name
command.
2. Refer to the Sun StorEdge T3 and
T3+ documentation.
restoret3config
•
$LUN
configuration is not found in
the
$restore_file
.
• Cannot restore
$LUN
.
1. Check for snapshot files in the
/opt/SUNWsecfg/etc/t3_name/
directory.
2. If the snapshot files are not found,
use the
modifyt3config
command to configure the Sun
StorEdge T3+ array.
rmt3group
An error occurred while removing
Group.
Refer to the Sun StorEdge T3 and T3+
array documentation.
rmt3slice
An error failed to remove slice
$slicename
.
Refer to the Sun StorEdge T3 and T3+
array documentation.
rmt3slice
An error failed to remove slice from
volume
$volume
.
1. Check the volume status using the
checkt3mount
or
showt3
command.
2. If unmounted, use the
restoret3config
command to
mount.
savet3config
While checking the configuration, the
Sun StorEdge T3+ array
configuration was not saved.
1. If the configuration is different
from standard Sun StorEdge T3+
array configuration, run the
showt3 -n t3_name
command.to
check the Sun StorEdge T3+ array
configuration.
2. Use the
modifyt3config
command to reconfigure the
device.
sett3lunperm
LUN
$lun
does not exist on the Sun
StorEdge T3+ array.
1. Create a Sun StorEdge T3+ array
slice.
2. Before setting permissions, use the
createt3slice
command.
TABLE B-3
Sun StorEdge T3+ Array Error Messages (Continued)
Source of Error Message
Cause of Error Message
Suggested Corrective Action