96
Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
TABLE 8-1
lists all of the events for the Sun StorEdge T3+ array.
TABLE 8-1
Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array
Component
Event
T
ype
Se
verity
Action
Description
Action
power.temp
Alarm+
The power temperature
is normal.
sysvolslice
Alarm
Yellow
Y
The vol slice feature is
possible in Sun StorEdge
T3+ array firmware
version 2.1 and above.
This option enables
volume slicing, up to 16
LUN per single Sun
StorEdge T3+ array or
partner group. This
feature also enables LUN
masking (HBA zoning)
features.
This option is disabled
by default. To activate
the feature, type
sys_enable_volslice_on
from the Sun StorEdge
T3+ array command line.
disk.port
Alarm-
Red
Y
The Sun StorEdge T3+
array has reported that
one port of a dual-ported
disk has failed.
1. Open a Telnet session
to the affected Sun
StorEdge T3+ array.
2. Verify disk state in
fru stat
,
fru list
,
and
vol stat
.