Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
Virtualization Engine Error Messages
TABLE B-1
Virtualization Engine Error Messages
Source of Error Message
Cause of Error Message
Suggested Corrective Action
Common to
virtualization engine
Invalid virtualization engine pair
name, or the virtualization engine is
unavailable. This is usually because
the
savevemap
command is running
Run
ps -ef | grep savevemap
or
listavailable -v
(which
returns the status of individual
virtualization engines) to confirm
that the configuration locks are set.
Common to
virtualization engine
No virtualization engine pairs were
found, or the virtualization engine
pairs are offline. This is usually due
to the
savevemap
command
running.
Run
ps -ef | grep savevemap
or
listavailable -v
(which
returns the status of individual
virtualization engines) to confirm
that the configuration locks are set.
Common to
virtualization engine
The virtualization engine was unable
to obtain a lock on
$vepair
.
Another virtualization engine
command is updating the
configuration.
1. Run
listavailable -v
(which
returns the status of individual
virtualization engines)
2. Check for the lock file directly by
using
ls -la
/opt/SUNWsecfg/etc
(look for
.v1.lock
or
.v2.lock
).
3. If the lock is set in error, use the
removelocks -v
command to
clear.
Common to
virtualization engine
The virtualization engine was unable
to start
slicd
on
${vepair
, so it
cannot execute the command.
1. Run
startslicd
and then
showlogs -e 50
to determine
why
startslicd
could not start
the daemon.
2. Reset or power off the
virtualization engine if the
problem persists.
Common to
virtualization engine
The login failed.
A password is required to log in to
the virtualization engine. The utility
uses the
VEPASSWD
environment
variable to login.
The environment variable
VEPASSWD
might be set to an incorrect value.
1. Set the
VEPASSWD
environment
variable with the proper value.
2. Try to login again.