Figure 3–1
Key Switch Positions
4
The fans in the power supplies begin turning.
4
The left front panel LED (green) turns on immediately denoting that the power
supply is delivering DC power.
4
The middle front panel LED (yellow) flashes while POST runs for
approximately 60 seconds. After 60 seconds, this LED turns off if the tests pass.
If the LED remains lit after 60 seconds, a test has failed.
4
The right front panel LED (green) flashes to show that boot is successful and
the operating system is running. If this LED fails to turn on and the middle
LED is on, a severe hardware fault exists.
Caution -
Never move the system when the power is on. Failure to heed this
warning may result in catastrophic disk drive failure. Always power the system off
before moving it.