Figure 2–7
Ethernet Cabling Length — Example Using N-type Cable
Note -
Sun equipment conforms to the Ethernet 10/100BASE-T standard, which
states that the 10/100BASE-T Link Integrity Test function should always be
enabled on both the host and the hub. If you have problems verifying connection
between Sun equipment and your hub, verify that your hub also has the link test
function enabled. Refer to Section 8.6.1, “Failure of Network Communications,” in
the Sun Enterprise 3500 System Reference Manual (part number 805-2630), and
refer to the manual provided with your hub for more information about the Link
Integrity Test function.
6. If all cables are connected, power on the system.
Connecting an ASCII Terminal
An ASCII terminal (or workstation) can be attached to the server to display
diagnostic messages produced by the firmware (power-on self-test/POST or
OpenBoot
TM
PROM/OBP) program. A terminal is not required for normal server
operations, so it may be necessary to locate a terminal to connect to the server.
1. Connect the terminal cable into serial port A on the clock+ board. See Figure
2–8.
18
Sun Enterprise 3500 System Installation Guide
♦
Revision A, April 1998
Содержание Enterprise 3500
Страница 2: ...USA 650 960 1300 fax 650 969 9131 ...
Страница 3: ...Sun Enterprise 3500 System Installation Guide Part No 805 2629 10 Revision A April 1998 ...
Страница 12: ...xi Sun Enterprise 3500 System Installation Guide Revision A April 1998 ...
Страница 20: ...8 Sun Enterprise 3500 System Installation Guide Revision A April 1998 ...
Страница 51: ...VCCI Regulatory Agency Compliance Statements 39 ...
Страница 52: ...Declaration of Conformity 40 Sun Enterprise 3500 System Installation Guide Revision A April 1998 ...
Страница 53: ...Index Index 41 ...