4
“How to Power Off the System” on page 55
4
“How to Remove the Chassis Foot Glides” on page 174
What to Do
1. Carefully turn the system chassis upside down.
Enlist the help of another person to accomplish this safely.
Do not lift the chassis using the plastic panels at the front or the side of the
chassis. Place the system onto a solid surface that spaces the unit about 2 inches
(5 cm) off the floor; for example, use a pair of wooden boards. Do not allow any
of the weight to rest on the plastic panels at the front of the chassis.
Note -
The right side of the casters assembly mounts to the two foot glide
mounting brackets on the underside of the chassis. If you removed these brackets
previously, you must reinstall them now. See “How to Install the Chassis Foot
Glides” on page 176.
2. Align the holes in the floor casters assembly with the corresponding mounting
holes on the underside of the chassis.
Position the casters assembly with the four casters facing up. Align the two large
holes in the assembly with the large holes in the chassis bottom.
Removing and Installing Miscellaneous Assemblies
173
Содержание Enterprise 250
Страница 2: ...USA 650 960 1300 fax 650 969 9131 ...
Страница 3: ...Sun Enterprise 250 Server Owner s Guide Part No 805 3389 11 Revision A June 1998 ...
Страница 44: ...10 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 45: ...CHAPTER 2 Photographic Tour of System System View 11 ...
Страница 46: ...Figure 2 1 1 Side Access Panel on page 19 12 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 48: ...Figure 2 2 14 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 50: ...Figure 2 3 12 Diskette Drive on page 22 16 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 52: ...Figure 2 4 18 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 69: ...Power Distribution Board Photographic Tour of System 35 ...
Страница 73: ...UltraSCSI Backplane Figure 2 20 For information related to this part see Photographic Tour of System 39 ...
Страница 88: ...54 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 102: ...68 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 160: ...126 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 212: ...178 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 226: ...Figure 9 8 192 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 228: ...194 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 266: ...232 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 310: ...276 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 324: ...290 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 330: ...296 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 346: ...312 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...
Страница 356: ...TABLE D 6 continued 322 Sun Enterprise 250 Server Owner s Guide Revision A June 1998 ...