40
7.3 Trailed DTS Calibration Procedure
1.
Open flap (1) to allow seed to flow out of the Air Transfer Pipe directly below the ORGA
Metering Outlet.
2.
Switch the scales ON and check units (kg). Zero the scales with the weight of the
calibration bag and Hanger.
3.
The calibration hanger and bag supplied with the DTS
can then be hooked onto the Air Transfer Pipe. (See
Right).
4.
Press the white prime button once. This will put the control box in calibration mode and
start the motor turning and metering seed.
5.
Press the white prime button once again to stop the motor once a
suitable sample is collected.
6.
The seed dispensed out of the ORGA Metering Unit can be
weighed using the digital weigh scales supplied with the drill.
7.
Close Calibration flap (1) after last calibration procedure
Ensure Calibration flap is shut after the calibration procedure.
NOTE: If a priming switch is deployed for calibration the calibration routine will commence.
Caution! Always Prime the ORGA Metering Unit before
Calibration
Press the Prime button fastened to the toolbox once. Then Press the
button again at the point where seed flows evenly from the outlet.
Empty contents of Calibration bag back into the hopper, Press ESC
on Control Box, then proceed to step 4.
1
Содержание DTS 3m
Страница 46: ...46 9 5 Coulter system 9 6 Fan Motor system...
Страница 47: ...47 9 7 Wings Markers system...