![Sumitomo HC-4A Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/sumitomo/hc-4a/hc-4a_technical-manual_1390617057.webp)
Troubleshooting
51
8.
Read the current draw for each lead, then stop the compressor.
•
A reading of 0 amperes indicates an open circuit.
•
A reading of 10 to 14 amperes (steady state) is normal.
•
A reading slightly higher than 10 to 14 amperes suggests possible minor system
problems, i.e. low-supply voltage, loose electrical connection, etc.
•
A reading of about 68 amperes indicates a mechanically locked rotor. Consult a SCAI
Service Center.
•
A reading of full scale, along with a tripped circuit breaker or a blown control circuit fuse,
means a short circuit in the chassis wiring or motor.
9.
Remove the ammeter.
10.
Replace the terminal block access cover.
Fan and Circulator
Fan motor and circulator motor checks for winding continuity, resistance and grounding will
isolate most fan motor and circulator motor electrical problems. When the checks indicate a
faulty fan motor or faulty circulator motor, a replacement is needed. Contact a SCAI Service
Center.
AVOID ELECTRIC SHOCK.
Disconnect the power to the compressor before
troubleshooting the electrical components.
AVOID INJURY FROM BURNS.
During operation, some surfaces under the
compressor’s cover become hot. Allow the compressor to cool for 1/2 hour after
shutdown before removing the cover for maintenance.
AVOID ELECTRIC SHOCK.
Permit only qualified electrical technicians to open
electrical enclosures, to perform electrical checks or to perform tests with the
power supply connected and wiring exposed. Failure to observe this warning can
result in serious injury or death.
Winding Continuity, Grounding and Resistance Checks—Fan and Circulator Motors
Tools required: Ohmmeter or multimeter
#2 Phillips screwdriver.
3 mm (1/8”) flat-blade screwdriver
1.
Disconnect the power to the compressor.
Содержание HC-4A
Страница 2: ......
Страница 6: ...iv This page is intentionally blank ...
Страница 10: ...4 This page is intentionally blank ...
Страница 12: ...6 This page is intentionally blank ...
Страница 14: ...8 This page is intentionally blank ...
Страница 36: ...30 This page is intentionally blank ...
Страница 38: ...32 This page is intentionally blank ...
Страница 59: ...Troubleshooting 53 Figure 8 HC 4A Wiring Diagram Main Electrical Chassis and Components ...
Страница 60: ...Troubleshooting 54 Figure 9 HC 4A2 Wiring Diagram Main Electrical Chassis and Components ...
Страница 61: ...Troubleshooting 55 Figure 10 HC 4A and HC 4A2 Wiring Diagram Air Cooled Unit ...
Страница 62: ...Troubleshooting 56 Figure 11 HC 4A Electrical Schematic ...
Страница 63: ...Troubleshooting 57 Figure 12 HC 4A2 Electrical Schematic Main Electrical Chassis and Components ...
Страница 64: ...Troubleshooting 58 Figure 13 HC 4A2 Electrical Schematic Air Cooled Unit ...
Страница 67: ...Parts 61 Figure 14 Parts Identification Fan Circulator and Air Heat Exchanger not shown 15 18 16 10 11 17 13 ...
Страница 68: ...Parts 62 Figure 15 Parts Identification for HC 4A 12 14 19 23 ...
Страница 69: ...Parts 63 Figure 16 Parts Identification for HC 4A2 12 14 19 23 ...
Страница 70: ...Parts 64 Figure 17 Parts Identification 29 28 30 31 ...