![Sumitomo HC-4A Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/sumitomo/hc-4a/hc-4a_technical-manual_1390617053.webp)
Troubleshooting
47
Problem
Possible Cause
Corrective Action
Compressor starts but shuts
down sometime later.
Water high-temperature
switch is open.
Check the coolant flow and
temperature. Refer to the
Specifications.
Circuit breaker or fuse is
open.
Reset the circuit breaker or
replace a fuse. Compare the
electric service with system
specifications. Consult a SCAI
Service Center if the problem
persists.
Component failure in the
power circuit.
Check for an open circuit
breaker or fuse. Reset or
replace if necessary. Check for
a faulty component.
Incorrect current draw.
Measure the current. Check
motor winding resistances.
If checks reveal failed motor
windings or a locked rotor,
consult
a SCAI S
ervice
C
enter
.
Compressor overload relay
opens.
If power check indicates the
utilities are within specifications,
interlocks may be faulty.
Consult a SCAI Service Center.
Fan or circulator runs slow or
is stopped.
See below at “Fan runs slow or
has stopped” or “Coolant flow
has stopped”.
Coolant loss is greater than
(1) liter.
Consult a SCAI Service Center.
System starts but gas
pressures are abnormally
high or low.
Wrong equalization pressure. Refer to Specifications and the
section on Charging and
Venting. Leak check the system
if the pressure is low.
Gas line couplings are not
fully engaged.
Be sure that all Aeroquip
couplings are fully engaged and
torqued.
Gas lines are connected
wrong.
Reconnect. See the Installation
section.
Compressor runs, but cold
head valve motor operation is
abnormal
Wrong cold head cable.
Be sure correct cold head cable
is connected (Page 56.)
Cold head problem.
Consult cold head manual.
Содержание HC-4A
Страница 2: ......
Страница 6: ...iv This page is intentionally blank ...
Страница 10: ...4 This page is intentionally blank ...
Страница 12: ...6 This page is intentionally blank ...
Страница 14: ...8 This page is intentionally blank ...
Страница 36: ...30 This page is intentionally blank ...
Страница 38: ...32 This page is intentionally blank ...
Страница 59: ...Troubleshooting 53 Figure 8 HC 4A Wiring Diagram Main Electrical Chassis and Components ...
Страница 60: ...Troubleshooting 54 Figure 9 HC 4A2 Wiring Diagram Main Electrical Chassis and Components ...
Страница 61: ...Troubleshooting 55 Figure 10 HC 4A and HC 4A2 Wiring Diagram Air Cooled Unit ...
Страница 62: ...Troubleshooting 56 Figure 11 HC 4A Electrical Schematic ...
Страница 63: ...Troubleshooting 57 Figure 12 HC 4A2 Electrical Schematic Main Electrical Chassis and Components ...
Страница 64: ...Troubleshooting 58 Figure 13 HC 4A2 Electrical Schematic Air Cooled Unit ...
Страница 67: ...Parts 61 Figure 14 Parts Identification Fan Circulator and Air Heat Exchanger not shown 15 18 16 10 11 17 13 ...
Страница 68: ...Parts 62 Figure 15 Parts Identification for HC 4A 12 14 19 23 ...
Страница 69: ...Parts 63 Figure 16 Parts Identification for HC 4A2 12 14 19 23 ...
Страница 70: ...Parts 64 Figure 17 Parts Identification 29 28 30 31 ...