Starting and stopping are the only operating procedures performed at the compressor.
Prestart Check
Before starting the compressor, be sure that all other system components to be used are
properly connected and ready for operation. Refer to the instructions supplied with the other
components.
When the compressor is at room temperature, 20° C (68° F), the pressure gauge should
indicate the equilibrium pressure stated in the specifications section. Higher or lower
temperatures will result in correspondingly higher or lower pressures, but these pressure
changes are normal. Abnormally lower readings indicate that some of the gas charge has been
lost. Refer to the Maintenance section for instructions on charging, cleaning and leak checking.
For HC-4A2 compressor only, set toggle switch on compressor front panel for 50 or 60 Hz
operation.
Starting
Close the circuit breaker by pushing up the handle.
Press the power switch.
The indicator in the switch will light. The compressor will start. Any items drawing power from
the compressor will start.
Stopping
At the compressor, press the power switch.
The indicator light in the switch will go off. The compressor will stop. Any items drawing power
from the compressor will stop.
Restarting after a Power Failure
If the compressor stops due to a power interruption, it is designed to restart immediately after
power has been restored. If the compressor stops for other reasons, refer to the
Troubleshooting section of this manual.
Содержание HC-4A
Страница 2: ......
Страница 6: ...iv This page is intentionally blank ...
Страница 10: ...4 This page is intentionally blank ...
Страница 12: ...6 This page is intentionally blank ...
Страница 14: ...8 This page is intentionally blank ...
Страница 36: ...30 This page is intentionally blank ...
Страница 38: ...32 This page is intentionally blank ...
Страница 59: ...Troubleshooting 53 Figure 8 HC 4A Wiring Diagram Main Electrical Chassis and Components ...
Страница 60: ...Troubleshooting 54 Figure 9 HC 4A2 Wiring Diagram Main Electrical Chassis and Components ...
Страница 61: ...Troubleshooting 55 Figure 10 HC 4A and HC 4A2 Wiring Diagram Air Cooled Unit ...
Страница 62: ...Troubleshooting 56 Figure 11 HC 4A Electrical Schematic ...
Страница 63: ...Troubleshooting 57 Figure 12 HC 4A2 Electrical Schematic Main Electrical Chassis and Components ...
Страница 64: ...Troubleshooting 58 Figure 13 HC 4A2 Electrical Schematic Air Cooled Unit ...
Страница 67: ...Parts 61 Figure 14 Parts Identification Fan Circulator and Air Heat Exchanger not shown 15 18 16 10 11 17 13 ...
Страница 68: ...Parts 62 Figure 15 Parts Identification for HC 4A 12 14 19 23 ...
Страница 69: ...Parts 63 Figure 16 Parts Identification for HC 4A2 12 14 19 23 ...
Страница 70: ...Parts 64 Figure 17 Parts Identification 29 28 30 31 ...