3. Transport

7

4. Installation

DANGER

-  Do not use the unit in an explosive atmosphere; otherwise, explosion, ignition, an electric shock, 

injury, a fire, or damage to the equipment may occur.

CAUTION

-  Do not use the products for purposes other than those shown on the nameplate or in the manu-

facturing specifications; otherwise, electric shock, personal injury, or damage to the equipment 
may result.

- Do not place inflammables around the product; otherwise, a fire may occur.
-  Do not place any objects that hinder ventilation around the product; otherwise, cooling effects 

may be reduced, leading to a fire hazard due to excessive heating.

-  Do not step on or hang from the product; otherwise, injury or damage to the equipment may 

result.

-  When the unit is used in equipment that is sensitive to oil contamination, install an oil pan or 

other such device to prevent grease leakage due to failure or wear; otherwise, grease leakage 
may damage products.

-  This product is driving device for automated guided vehicles (AGVs). It cannot be used in other 

applications, such as driving device for elevators.

4-1  Location of Installation

Ambient temperature: −10 to +40°C
Ambient humidity: 85% max.
Altitude: 1000m max.
Ambient atmosphere  - There should be no corrosive gas, explosive gas, or steam.
 

- The location should be well ventilated and free from dust.

Installation locations  - Indoor areas with little dust (IP54 protection class, dust and splash proof)
 

- Vibration: 1G max.

-  Mounting In conditions other than above requires optional specifications. Please consult with us.
-  Drives fabricated according to special specifications, such as outdoor use types, can be used in the 

specified mounting environments. However, concerning the connector to the machine used, imple-
ment measures based on the Mounting environment.

- Mount In a location that enables easy operation, such as inspection and maintenance.
- Mount in a sufficiently rigid casing.

4-2  Mounting Angle

Possible mounting angle for this product is only horizontal output shaft direction. Please do not use this 
drive at any other shaft mounting angle.
Note, however, that if the product is manufactured according to your designated mounting angle, do 
not use it at any other mounting angle.

Содержание Smartris

Страница 1: ...be handled by only those who have been trained for the work Please read this manual carefully before use Deliver this manual to the customer who will actually use the product This instruction manual...

Страница 2: ......

Страница 3: ...handling may result in physical damage and or personal injury Matters described in CAUTION may lead to serious danger depending on the situation Be sure to observe important matters described herein D...

Страница 4: ...vo Drive Unit Maintenance Manual No DM1802E Contents Introduction Safety Precautions 1 Introduction Reading the Maintenance Manual Table of Contents 2 1 Receiving Inspection 3 2 Storage 5 3 Transport...

Страница 5: ...red 2 Was any part broken during transport 3 Are all bolts and nuts tightened firmly 1 1 Reading the Nameplates When contacting the company please provide 1 Gearmotor nomenclature 2 Reduction ratio an...

Страница 6: ...omenclature matches the order Model Symbol C ALTAX NEO Frame Size 5087E 5097E 5097P 5107P Output Shaft Direction H Horizontal Output Shaft Reduction Ratio Mounting Style F Flange Mount With or Without...

Страница 7: ...Rust prevention oil is applied before shipping from the factory Confirm rust prevention conditions every six months after delivery and reapply rust prevention measures as needed Internal rust preventi...

Страница 8: ...sport Before hoisting check the weight with the nameplate crate outline drawing catalog etc Never hoist the product that exceeds load capacity of the crane or other mechanism being used to lift it oth...

Страница 9: ...annot be used in other applications such as driving device for elevators 4 1 Location of Installation Ambient temperature 10 to 40 C Ambient humidity 85 max Altitude 1000m max Ambient atmosphere There...

Страница 10: ...om the anti load side Reverse rotation of general motors for Japan s domestic market Note that changing the phase sequence of the U V W wiring will prevent this product from operating and may cause ma...

Страница 11: ...ti fretting agent to spigot Fix the wheel with a bolt Spigot Size S M Frame Size 5087E 5097E Spigot B 25H7 25H7 Tightening Bolt Q ty 10 8 Size M6 M8 Strengthening Classification 12 9 12 9 Tightening T...

Страница 12: ...ing Torque N m 8 0 13 6 O ring nitrile rubber Designation AS568 261 G 140 Thickness Inner diameter 3 53 171 04 3 1 139 4 2 Mounting Gearmotor Fasten the bolt on the AGV main unit or mounting part Size...

Страница 13: ...re The motor is not equipped with a protection device However it is compulsory to install an over load protector according to facility electrical codes It is recommended to install other protective de...

Страница 14: ...jury or damage to the equipment CAUTION Do not put fingers or foreign objects into the opening of the product otherwise electric shock injury fire or damage to the equipment may result The product bec...

Страница 15: ...se generating reso nance Is the shaft center aligned with the AGV main unit Is vibration from the AGV main unit transmitted to this prod uct Is the surface temperature abnormally high Does the voltage...

Страница 16: ...c shock may result Do not operate the unit without a safety cover removed during inspection to shield rotating parts otherwise loose clothing may became caught in these rotating parts and cause seriou...

Страница 17: ...ed maintenance shop 8 2 Main Unit Maintenance Because the gear unit is filled with long lasting grease it can be used for long time without replenishing the grease but maintenance with disassembly aft...

Страница 18: ...motor runs in the reverse di rection Wiring error Change the connection Fuse tripping The lead wire is short circuited Confer with authorized maintenance shop Poor contact between motor and starter Ma...

Страница 19: ...ges Increase the time for speed changes Extreme load fluctuation Decrease load fluctuation Overcurrent due to ground fault Ground fault on output side Take measures to prevent ground fault Direct curr...

Страница 20: ...Number Part Name Part Number Part Name 1 Output Shaft 7 Spacer Ring 13 Joint Spline 19 Carrier Pin Pipe 2 Oil Seal 8 Slow Speed Shaft Pin 14 Intermediary Flange 20 Cycloid Disc 3 Bearing 9 Frame 15 Ca...

Страница 21: ...t Spline 15 Distancing Piece 22 Adapter 2 Ring Gear Housing Pin 9 Bearing 16 Central Shaft 23 Spacer Ring 3 Carrier Bolt 10 Carrier Nut 17 Slow Speed Shaft Roller 24 O ring 4 Spacer Ring 11 Bearing 18...

Страница 22: ...ges Exclusion from the warranty The following items will be excluded from the warranty 1 A breakdown resulting from defects in the mounting of the product and connection with other devices etc 2 A bre...

Страница 23: ......

Страница 24: ...48011 Bilbao Vizcaya Spain TEL 34 9448 05389 FAX 34 9448 01550 United Kingdom SM Cyclo UK Ltd SMUK Unit 29 Bergen Way Sutton Fields Industrial Estate Kingston upon Hull HU7 0YQ East Yorkshire United...

Отзывы: