The configuration tool of PROFIBUS-DP master sets the input and output data length of
PROFIBUS-DP Option from Extended Data 1 (32 bytes), Extended Data 2 (12 bytes), and
Basic Data (6 bytes).
■
High-Speed I/O Data
High-speed I/O data is directly transferred to or from the drive and can control the drive. For
example, when the drive is set for PROFIBUS-DP communications, the drive Run/Stop and
Frequency Reference commands are typically transferred to the drive within 2 ms after
being received by the option.
■
MEMOBUS/Modbus Message
MEMOBUS/Modbus message data is transferred to the drive using MEMOBUS/Modbus
messages. All drive parameters and data can be accessed through MEMOBUS/Modbus.
Because the data in this message type is transferred to the drive after the PROFIBUS-DP
Option receives and edits it, more time is required to return the data to the master. The
master must synchronize the timing of sending and receiving the data by handshaking.
■
Memory Maps
The following memory maps show the I/O data bytes.
■
Basic and Extended Register Maps
Basic Data
(6 bytes)
Extended Data 1
(32 bytes)
Extended Data 2
(12 bytes)
High-speed I/O Data
Bytes 0 to 5
Bytes 0 to 15
Bytes 0 to 3
MEMOBUS/Modbus
Data
–
Bytes 16 to 31
Bytes 4 to 11