36
MAINTENANCE
SUBMIT OIL SAMPLE
1.
Fill out all the information on the oil sample label (3A) provided
with the oil analysis kit.
2.
Peel the top label (3A) off and stick it onto the clear bottle (2).
3.
Write the name of the company submitting the oil sample on the
lines provided on the bottom label (3b) and stick it on the black
canister (1).
4.
Place the oil sample bottle (2) inside the black canister and put
the lid on.
5.
Mail the sample to:
C/O Lube Analysis
Sullivan-Palatek, Inc.
1201 West US Hwy 20
Michigan City, IN 46360
INTERPRET RESULTS
The results of the oil analysis will be given to the sender of the sample
by Sullivan-Palatek. The analysis report includes customer unit infor-
mation, sample data, spectrochemical analysis, physical properties,
additional test results and analysis recommendations. If previous oil
samples have been submitted for analysis, that information will also
be on the report. Information to assist in understanding the analysis
report is included on the front of the report.
FIGURE 6-3.
MAIL ANALYSIS KIT