56
TROUBLESHOOTING
7.1
INTRODUCTION
This section contains instructions for troubleshooting the equipment following a malfunction. Each
symptom of trouble for a component or system is followed by a list of probable causes of the trouble and
suggested procedures to be followed to eliminate the cause.
The procedures listed should be performed in the order in which they are listed, although the order may be
varied if the need is indicated by conditions under which the trouble occurred. In any event, the procedures,
which can be performed in the least amount of time and with the removal or disassembly of the fewest
parts, should be performed first.
7.2
COMPRESSOR WILL NOT START
POSSIbLE CAUSE
REMEDY
Main disconnect switch open
Close switch.
Line fuse(s) blown
Replace fuse(s).
Control circuit breaker tripped
Reset breaker.
Motor overload
Reset motor starter overload.
If machine still will not start, check sizing and adjustment of
overloads.
Check motor starter contacts for pitting.
Low incoming line voltage
Check all voltages. If voltage is low or imbalanced, consult power
company.
Open compressor discharge temperature
(CDT) sensor
Replace CDT sensor.
Defective control relay
Replace control relay (when applicable).
Power failure
Refer to
Unit filled with oil
Inlet valve is leaking. Replace inlet valve.
Unit failure
Replace unit.
7.3
MACHINE WILL NOT bUILD UP FULL DISCHARGE PRESSURE
POSSIbLE CAUSE
REMEDY
Air demand is too great
Repair system air leaks, Add compressor capacity to satisfy
demand.
Dirty air filter
Change element as required.
Solenoid valve defective
Repair or replace solenoid valve.
7.4
RECEIVER PRESSURE VENTING THROUGH bLOWDOWN
POSSIbLE CAUSE
REMEDY
Defective check valve portion of minimum
pressure valve
Repair or replace check valve.
7.5
MACHINE SHUTS DOWN WITH AIR DEMAND PRESENT
POSSIbLE CAUSE
REMEDY
Loss of control voltage
Reset breakers. If trouble persists, check transformer voltages.
Low incoming voltage
Consult power company.
Excessive operating pressure
Improperly adjusted or defective control pressure. Readjust or
replace. Check unload pressure settings.
Separator requires maintenance. Check separator differential
under full load conditions. Differential pressure should be less
than 10 psi.
Open compressor discharge temperature (CDT)
Monitor temperature: normal operating discharge temperature
should be 160–220°F (100°F above ambient). Shutdown is set at
240°F.
Cooling airflow restricted. Clean cooler and check for proper
ventilation.
Ambient temperature is too high. Provide sufficient ventilation.
Low lubricant level. Add lubricant.
Clogged oil filter. Change oil filter element.
Cooler thermostat not functioning properly. Replace thermostat.
Defective CDT sensor. Replace CDT sensor.
Содержание 15D
Страница 6: ...vi About This Manual ...
Страница 12: ...4 Introduction ...
Страница 20: ...12 Specifications 2 2 DIMENSIONS OPEN BASE MOUNT AIR COOLED Figure 2 1 GA 15 40D AC BM OPEN ...
Страница 21: ...13 Specifications 2 3 DIMENSIONS ENCLOSED BASE MOUNT AIR COOLED Figure 2 2 GA 15 40D AC BM VERT ENCL ...
Страница 22: ...14 Specifications 2 4 DIMENSIONS OPEN BASE MOUNT WATER COOLED Figure 2 3 GA 15D 30D WC BM HORZ OPEN GAUGES ...
Страница 23: ...15 Specifications 2 5 DIMENSIONS ENCLOSED BASE MOUNT WATER COOLED Figure 2 4 GA 15 40D WC BM ENCL GAUGES ...
Страница 24: ...16 Specifications 2 6 DIMENSIONS OPEN PLATFORM MOUNT AIR COOLED Figure 2 5 GA 15 40D AC PLAT OPEN GAUGES ...
Страница 25: ...17 Specifications 2 7 DIMENSIONS ENCLOSED PLATFORM MOUNT AIR COOLED Figure 2 6 GA 15 40D AC PM VERT ENCL ...
Страница 30: ...22 Specifications 2 12 PIPING AND INSTRUMENTATION AIR COOLED Figure 2 11 GA P I S R02 ...
Страница 31: ...23 Specifications 2 13 PIPING AND INSTRUMENTATION WATER COOLED Figure 2 12 P I 15 40 WC GAUGES R00 ...
Страница 34: ...26 Specifications ...
Страница 66: ...58 Troubleshooting ...
Страница 84: ...76 Parts Catalog 8 10 AIR INLET ASSEMBLY 15 30HP 13 12 11 13 12 4 5 2 3 14 1 Figure 8 6 AS805 030D7H TE R00 ...
Страница 88: ...80 Parts Catalog 8 12 AIR INLET ASSEMBLY 40HP 14 15 5 15 4 3 2 13 1 Figure 8 8 AS805 040DS TE REV 00 ...
Страница 112: ...NOTES ...
Страница 113: ...NOTES ...