______________________________SULLIVAN-PALATEK
24
6.5 PRESSURE
ADJUSTMENT
Note: prior to making any control pressure adjustments, turn the adjusting screw on the
modulating (or regulating) valve in several turns to get it out of the action. Once the
control has been set, then the regulating (or modulating) valve is re-adjusted so that it
starts operating (as determined by air coming out the vent hole in cap) at 5 PSIG lower
pressure than the control set pressure.
In order to change the control (unload) pressure and/or the unload pressure settings; the
following procedures must be used:
A. Both the unload and load pressures are set by going into the ‘Operations’ menu,PO1
B. To change any pressure, the access code 0009 must be entered.
C. Press the ‘up’ (+) and ‘down’ (-) keys simultaneously
D. Press ‘enter’ key several times until last digit is flashing.
E. Now use down (-) key to get to 0009
F. Press ‘enter’ key, then down (-) key to enter menu PO1.
G. Press ‘enter’ key twice, then use up or down keys to change the unload pressure Pu.
H. Now press ‘enter’ to store this setting.
I. Press down (-) key to get to the load pressure Pl. (this is normally set at a pressure 8
to 12 PSI below the unload pressure)
J. Press ‘enter’, then use up (+) or down (-) keys to change setting.
K. Press ‘enter’ to store setting
L. Press ‘reset’ (double bar) for 2 seconds to return to normal display.
M. Press down (-) arrow to get the temperature display.
6.6 SERVICE/MAINTENANCE PROCEDURES
All service parameters are located in menu PO4. In order to change any of these
settings access code 0100 must be selected:
A. Simultaneously press ‘up’ (+) and ‘down’ (-) keys.
B. Press ‘enter’ to advance the digits.
C. Use the ‘up’ (+) or ‘down’ (-) keys to select the appropriate digit.
D. When the correct code is shown press ‘enter’ again.
E. Use the ‘up’ (+) or ‘down’ (-) key to select the appropriate menu (i.e. PO4)
F. Press ‘enter’ and then press the ‘up’ (+) or ‘down’ (-) keys to pick the setting to be
changed. (H3 air filter, H4 oil change, H5 separator change, H6 oil filter service)
G. Press ‘enter’
H. Press ‘enter again, and then use the ‘up’ (+) or ‘down’ (-) key to change the setting.
I. Press ‘enter’ to record this change.
J. Use the ‘up’ (+) or ‘down’ (-) key to pick other settings to be changed.
K. Once the desired settings have been changed, press the ‘C’ twice (or hold the ‘reset’
for 2 seconds) to return to the main menu.
Содержание 125G
Страница 12: ...______________________________SULLIVAN PALATEK 12 CONTROL SCHEMATIC ...
Страница 17: ...SULLIVAN PALATEK______________________________ 17 4 5a WIRING DIAGRAM FULL VOLTAGE STARTER STANDARD ...
Страница 18: ...______________________________SULLIVAN PALATEK 18 4 5b WIRING DIAGRAM Y DELTA START OPTIONAL ...
Страница 28: ...______________________________SULLIVAN PALATEK 28 PARTS LISTING ...
Страница 31: ...SULLIVAN PALATEK______________________________ 31 DRIVE AND BASE ASSEMBLY ...
Страница 32: ...______________________________SULLIVAN PALATEK 32 7 3 DRIVE AND BASE ASSEMBLY PARTS LIST ...
Страница 33: ...SULLIVAN PALATEK______________________________ 33 LUBRICATION AND COOLING SYSTEM AIR COOLED ...
Страница 34: ...______________________________SULLIVAN PALATEK 34 7 4 LUBRICATION AND COOLING SYSTEM AIR COOLED ...
Страница 35: ...SULLIVAN PALATEK______________________________ 35 LUBRICATION AND COOLING SYSTEM WATER COOLED 125 150 ...
Страница 36: ...______________________________SULLIVAN PALATEK 36 7 5a LUBRICATION AND COOLING SYSTEM WATER COOLED 125 150 ...
Страница 37: ...SULLIVAN PALATEK______________________________ 37 LUBRICATION COOLING SYSTEM W C 200 250 ...
Страница 38: ...______________________________SULLIVAN PALATEK 38 7 5b LUBRICATION COOLING SYSTEM W C 200 250 ...
Страница 39: ...SULLIVAN PALATEK______________________________ 39 INLET AND CAPACITY CONTROL SYSTEM ...
Страница 41: ...SULLIVAN PALATEK______________________________ 41 DISCHARGE SYSTEM 125 150 HP ...
Страница 43: ...SULLIVAN PALATEK______________________________ 43 DISCHARGE SYSTEM 200 250 HP ...
Страница 45: ...SULLIVAN PALATEK______________________________ 45 OPEN COMPRESSOR ELECTRICAL CONTROL PARTS ...
Страница 46: ...______________________________SULLIVAN PALATEK 46 7 8a OPEN COMPRESSOR ELECTRICAL CONTROL PARTS ...
Страница 47: ...SULLIVAN PALATEK______________________________ 47 ENCLOSED COMPRESSOR CONTROL PARTS ...
Страница 48: ...______________________________SULLIVAN PALATEK 48 7 8b ENCLOSED COMPRESSOR CONTROL PARTS ...
Страница 49: ...SULLIVAN PALATEK______________________________ 49 AIR COOLED ENCLOSURE 125 250 ...
Страница 50: ...______________________________SULLIVAN PALATEK 50 7 10a AIR COOLED ENCLOSURE 125 150 ...
Страница 51: ...SULLIVAN PALATEK______________________________ 51 AIR COOLED ENCLOSURE 200 250 ...
Страница 52: ...______________________________SULLIVAN PALATEK 52 7 10b AIR COOLED ENCLOSURE 200 250 ...
Страница 53: ...SULLIVAN PALATEK______________________________ 53 WATER COOLED ENCLOSURE ...
Страница 54: ...______________________________SULLIVAN PALATEK 54 7 11 WATER COOLED ENCLOSURE ...
Страница 56: ...______________________________SULLIVAN PALATEK 56 7 12b DECAL AND IDENTIFICATION ...
Страница 58: ...______________________________SULLIVAN PALATEK 58 8 2 GENERAL ARRANGEMENT OPEN AIR COOLED 125 250 ...
Страница 59: ...SULLIVAN PALATEK______________________________ 59 8 3 GENERAL ARRANGEMENT OPEN WATER COOLED 125 250 ...
Страница 60: ...______________________________SULLIVAN PALATEK 60 8 4 GENERAL ARRANGEMENT ENCLOSED AIR COOLED 125 150 ...
Страница 61: ...SULLIVAN PALATEK______________________________ 61 8 5 GENERAL ARRANGEMENT ENCLOSED AIR COOLED 200 250 ...
Страница 62: ...______________________________SULLIVAN PALATEK 62 8 6 GENERAL ARRANGEMENT ENCLOSED WATER COOLED 125 250 ...