A sight gauge is provided to monitor the lubricoolant level in the oil separation tank, and
a capped oil fill port is provided to keep the oil the proper level and to refill the system
after changing the lubricoolant.
WARNING: Do not remove caps, plugs or other components or connections while
the compressor is running or pressurized. Shut the compressor off, open and
lock out the electrical disconnect switch, and relieve all sump pressure before
doing so.
The oil separation tank is ASME rated for 200 psig (1380 kPa) maximum working
pressure. A combination minimum-pressure/check valve in the separator cover assures
a minimum pressure of 60 psig (415 kPa) for proper lubricoolant circulation and
separation. At the same time it prevents a reverse flow of compressed air from an
auxiliary air receiver and/or the plant air-main back through the compressor at shutdown
or during periods of unloaded operation.
A pressure relief valve (located upstream, or on the “wet” side of the separator) is set to
open if a control malfunction would allow the pressure to exceed 200 psig (1380 kPa).
However, since the opening of this valve is noisy and results in hot oil being expelled,
the micro processor control has been set to shut the motor off @ 10 psi above the
control.
The panel-mounted micro processor shows the pressure at the discharge of the MPV.
(I.e. line pressure). Additionally, differential pressure switches which trip if the pressure
drop across the oil filter and the separator element are too high, and will indicate such by
a fault signal.
The compressor discharge temperature is also displayed on the micro processor screen.
Normal discharge temperature should be approximately 180-220° F (82-105° C), or
about 100° F (38° C) above ambient.
The micro processor is programmed to shut off the compressor should the discharge
temperature exceed 240° F. Should this occur, check for adequate lubricant, cooling fan
operation, dirty cooler, or varnish in oil & cooler.
DISCHARGE SYSTEM SCHEMATIC
Содержание 125G
Страница 12: ...______________________________SULLIVAN PALATEK 12 CONTROL SCHEMATIC ...
Страница 17: ...SULLIVAN PALATEK______________________________ 17 4 5a WIRING DIAGRAM FULL VOLTAGE STARTER STANDARD ...
Страница 18: ...______________________________SULLIVAN PALATEK 18 4 5b WIRING DIAGRAM Y DELTA START OPTIONAL ...
Страница 28: ...______________________________SULLIVAN PALATEK 28 PARTS LISTING ...
Страница 31: ...SULLIVAN PALATEK______________________________ 31 DRIVE AND BASE ASSEMBLY ...
Страница 32: ...______________________________SULLIVAN PALATEK 32 7 3 DRIVE AND BASE ASSEMBLY PARTS LIST ...
Страница 33: ...SULLIVAN PALATEK______________________________ 33 LUBRICATION AND COOLING SYSTEM AIR COOLED ...
Страница 34: ...______________________________SULLIVAN PALATEK 34 7 4 LUBRICATION AND COOLING SYSTEM AIR COOLED ...
Страница 35: ...SULLIVAN PALATEK______________________________ 35 LUBRICATION AND COOLING SYSTEM WATER COOLED 125 150 ...
Страница 36: ...______________________________SULLIVAN PALATEK 36 7 5a LUBRICATION AND COOLING SYSTEM WATER COOLED 125 150 ...
Страница 37: ...SULLIVAN PALATEK______________________________ 37 LUBRICATION COOLING SYSTEM W C 200 250 ...
Страница 38: ...______________________________SULLIVAN PALATEK 38 7 5b LUBRICATION COOLING SYSTEM W C 200 250 ...
Страница 39: ...SULLIVAN PALATEK______________________________ 39 INLET AND CAPACITY CONTROL SYSTEM ...
Страница 41: ...SULLIVAN PALATEK______________________________ 41 DISCHARGE SYSTEM 125 150 HP ...
Страница 43: ...SULLIVAN PALATEK______________________________ 43 DISCHARGE SYSTEM 200 250 HP ...
Страница 45: ...SULLIVAN PALATEK______________________________ 45 OPEN COMPRESSOR ELECTRICAL CONTROL PARTS ...
Страница 46: ...______________________________SULLIVAN PALATEK 46 7 8a OPEN COMPRESSOR ELECTRICAL CONTROL PARTS ...
Страница 47: ...SULLIVAN PALATEK______________________________ 47 ENCLOSED COMPRESSOR CONTROL PARTS ...
Страница 48: ...______________________________SULLIVAN PALATEK 48 7 8b ENCLOSED COMPRESSOR CONTROL PARTS ...
Страница 49: ...SULLIVAN PALATEK______________________________ 49 AIR COOLED ENCLOSURE 125 250 ...
Страница 50: ...______________________________SULLIVAN PALATEK 50 7 10a AIR COOLED ENCLOSURE 125 150 ...
Страница 51: ...SULLIVAN PALATEK______________________________ 51 AIR COOLED ENCLOSURE 200 250 ...
Страница 52: ...______________________________SULLIVAN PALATEK 52 7 10b AIR COOLED ENCLOSURE 200 250 ...
Страница 53: ...SULLIVAN PALATEK______________________________ 53 WATER COOLED ENCLOSURE ...
Страница 54: ...______________________________SULLIVAN PALATEK 54 7 11 WATER COOLED ENCLOSURE ...
Страница 56: ...______________________________SULLIVAN PALATEK 56 7 12b DECAL AND IDENTIFICATION ...
Страница 58: ...______________________________SULLIVAN PALATEK 58 8 2 GENERAL ARRANGEMENT OPEN AIR COOLED 125 250 ...
Страница 59: ...SULLIVAN PALATEK______________________________ 59 8 3 GENERAL ARRANGEMENT OPEN WATER COOLED 125 250 ...
Страница 60: ...______________________________SULLIVAN PALATEK 60 8 4 GENERAL ARRANGEMENT ENCLOSED AIR COOLED 125 150 ...
Страница 61: ...SULLIVAN PALATEK______________________________ 61 8 5 GENERAL ARRANGEMENT ENCLOSED AIR COOLED 200 250 ...
Страница 62: ...______________________________SULLIVAN PALATEK 62 8 6 GENERAL ARRANGEMENT ENCLOSED WATER COOLED 125 250 ...