OUTLET VALVE ASSEMBLY
SECTION
A5
A5.1 Outlet Housing Removal.
Remove outlet flange nuts, head bolts and nylon pipes. Take care when removing the valve strike plate
A5.2 Outlet valve disc removal
Remove valve and spring from guide, secure valve stem and unscrew retaining nut. Inspect strike plate
before re-fitting.
For re-assembly follow reverse procedure. Always fitting new graphite gaskets, seals and o-ring on
centre retaining bolt.