8.1 - POOR DEWPOINT
Page 31 of 36
VISUAL INDICATION
Low reading on
hygrometer
Moisture
downstream
Low dewpoint
POSSIBLE CAUSE
Faulty sensor
No flow rate across
sensor
Insuficient purge air
Entrained water
Low inlet pressure
High inlet temperature
Overflow of dryer
Dryer failure to cycle
Failure to switch, all
gauges showing line
pressure
High pressure drop
across dust filter
CHECK
Check by using other
sensor
Flow at exhaust from
sensor block
Check using
rotometer
Check all drains
Gauges and dryer
sizing
Using temperature
gauge
Flow rate through
dryer and dryer
sizing.
Check timer cycle
Check solenoid
valves
for leaks.
Check exhaust valve.
Desiccant attrition.
REMEDY
Change sensor
Adjust flow restrictor to
within spec.
Adjust if necessary
Repair if necessary
Resize compressor or
reduce air demand
Check compressor
after cooler
Adjust compressor
output, resize, Fit
100% flow control
devices (FCD)
Trace fault using other
fault charts.
Change valves.
Change Exhasut valve
seals.
Change desiccant.