5
-
II - D
IAGNOSTIC
PROCEDURES
D
IAG
-3
3 - A
PPLICATION
RATE
DIFFERENCE
BETWEEN
LEFT
-
HAND
SIDE
/
RIGHT
-
HAND
SIDES
Application rate diffe-
rence left-hand side/
right-hand side
Are the two electric actuators
working?
(Test from the diagnostics page)
(Sheet D1.2)
NO
YES
Check the settings of
the application rate
regulator (Sheet B1)
Reverse the electric
actuators in the
connection box
(Sheet A3)
Mechanically check
the calibration of the
shutters at mark 49
(Sheet B2)
Set the electric actua-
tors to mark 35
(Sheet B4)
Check if the shutter
slides freely (Sheet B5)
Check if the Stop & Go
actuators work
correctly
The faulty electric
actuator still does not
work
Inversion of the
phenomenon
Replacing the ECU
(Sheet A3)
Replace the actuator
and perform a CAL 35
(Sheet B4)
N
AME
: T
RAINING
D
EPARTMENT
D
ATE
: 2017
P
AGE
:
54 / 59
R
EFERENCE
: T
ECHNICIAN
’
S
O
PERATING
M
ANUAL
X40+-X50+ ISOBUS
I
ND
03