N
AME
: T
RAINING
D
EPARTMENT
D
ATE
: 2017
P
AGE
:
9 / 59
R
EFERENCE
: T
ECHNICIAN
’
S
O
PERATING
M
ANUAL
X40+-X50+ ISOBUS
I
ND
03
+
+
5
-
M
ECHANICAL
CALIBRATION
OF
THE
SHUTTERS
B2
ᇗ
With the spreader empty and the Stop & Go shutters open.
ᇗ
Remove the shaft of the application rate electric actuators.
ᇗ
Place a
Ø 35 mm
round bar
1
in the shutter opening (towards the front). Then lower the shutter using the lever.
ᇗ
The
Ø 35 mm
round bar must be in contact with the bottom and the front of the opening and touch the plastic shutter.
Under these conditions the index of the application rate lever must be at
mark 49
2
ᇗ
If this is not the case, the index is mounted on slot
3
, and therefore it must be moved in front of mark 49.
ᇗ
Perform this adjustment identically on both sides
2
3
1