October 7, 2012
115-V 20-Amp 60-Hz Self-Timed Unit
7
TESTING AND OPERATION
After.the.mounting.and.all.connections.are.complete,.test.the.SUITMATE
®
.unit.as.follows:
1).Make.certain.all.packaging.material.is.removed.from.the.unit.including.material.around.the.Motor.
2).Check.to.see.that.the.Basket.is.empty.and.that.the.Lid.moves.freely.
3).Press.down.on.the.Lid..The.unit.will.start.and.run.for.8.seconds..While.the.unit.is.running.it.should.run.
....smoothly.and.there.should.be.no.excessive.vibration.or.noise.
4).Releasing.the.lid.before.the.unit.automatically.stops.causes.the.Basket.to.stop.within.one.(1).second.
5).Test.the.SUITMATE
®
.unit.by.putting.a.wet.swimsuit.in.the.unit.according.to.the.instructions.on.the.underside
....of.the.Lid..If.there.is.excessive.vibration.or.noise.it.is.usually.caused.by.the.improper.loading.of.the.
....swimsuit..Be.certain.that.the.swimsuit.is.pushed.to.the.bottom.of.the.Basket.and.that.all.material.is.at.least.
....two.inches.below.the.top.of.the.Basket.
INSTALLATION TROUBLESHOOTING
If.the.SUITMATE
®
.unit.does.not.operate,.check.the.following:
1).Check.to.see.if.there.is.power.to.the.unit..Check.the.circuit.using.an.A.C..voltmeter.set.to.the.appropriate.
....range;.measure.across.the.“LINE”.side.of.the.GFCI.
2).Make.certain.that.the.GFCI.switch.is.in.the.“ON”.position...
3).Check.the.connections.on.the.GFCI.Junction.Box..Be.certain.there.is.power.on.the.“LOAD”.side.of.
....the.GFCI.
4).Check.the.SUITMATE
®
.UNIT.TROUBLESHOOTING.section.in.this.manual.for.additional.troubleshooting
....assistance.
FINISHING THE INSTALLATION
Be.certain.to.save.this.SUITMATE
®
.UNIT.MANUAL.for.future.reference..If.you.have.any.concerns.about.the.
correct.installation.of.the.SUITMATE
®
.unit,.please.contact.Extractor.Corporation.at:.(Telephone).800-553-3353,
(Fax).847-742-3552,.or.(E-Mail)[email protected].
With.proper.installation,.use,.and.maintenance.your.SUITMATE
®
.Swimsuit.Water.Extractor.will.provide.you.
with.years.of.trouble-free.service.
POSTING THE WALL SIGN
Locate.the.top.edge.of.the.sign.60+/-.1/16”.(1524.+/-.2mm).above.the.floor.centered.over.the.SUITMATE
®
.unit...
At.this.height.the.sign.will.not.be.blocked.when.the.lid.is.raised..It.will.also.serve.as.a.stop.to.keep.the.Lid.from.
striking.the.wall.behind.the.unit.
The.sign.has.an.adhesive.foam.backing..Be.certain.the.surface.that.the.sign.is.to.be.mounted.to.is.clean.and.
dry..Without.touching.the.sign.to.the.wall,.align.the.top.of.the.sign.60+/-.1/16”.(1524.+/-.2mm).above.the.floor.
and.at.the.center.of.the.unit..Press.the.sign.to.the.wall.and.rub.firmly.over.the.adhesive.portion.of.the.sign.