October 7, 2012
115-V 20-Amp 60-Hz Self-Timed Unit
43
ELECTRICAL ASSEMBLIES
115-V 20-Amp 60-Hz Self-Timed Unit
GENERAL
When.servicing.the.SUITMATE
®
.unit,.observe.the.following.safety.precautions:
Always.turn.off.the.power.at.the.circuit.breaker.–.place.a.lockout.tag.on.the.circuit.breaker.panel.indicating.that.
the.breaker.is.not.to.be.turned.on.except.by.authorized.personnel.–.and.disconnect.the.unit.before.doing.any.
work.on.the.SUITMATE
®
.unit..Simply.turning.off.a.switch.is.NOT.enough.
Use.only.proper.tools,.test.equipment,.and.work.practices.when.servicing.the.SUITMATE
®
.unit..If.there.are.any.
questions.concerning.proper.tools,.equipment.or.practices,.please.contact.the.factory.for.recommendations.at:.
(Telephone).(800).553-3353,.(Fax).847-742-3552,.or.(E-Mail)[email protected].
Due.to.critical.tolerances,.use.only.specified.replacement.parts..See.the.SUITMATE
®
.UNIT.PARTS.AND
ASSEMBLIES.list.in.this.manual.
REMOVE AND REPLACE GFCI
The.GFCI.can.be.serviced.from.the.bottom.of.the.unit.without.removing.the.unit.from.the.wall.
Do this FIRST
Make.certain.you.have.all.the.correct.parts.and.fasteners.necessary.for.correct.installation..Parts.used.in.this.
process:.(1).AEC2009.GFCI.115V.60Hz.
REMOVE GFCI
1).Turn.off.the.main.electrical.power.to.the.unit.–.place.a.lockout.tag.on.the.circuit.breaker.panel.indicating.that.
....the.breaker.is.not.to.be.turned.on.except.by.authorized.personnel,.and.disconnect.the.unit.before.doing.any.
....work.on.the.SUITMATE
®
.unit..Simply.turning.off.a.switch.in.NOT.enough.
2).Remove.the.cover.of.the.weatherproof.Junction.Box.that.contains.the.GFCI...Set.the.cover.and.(2).screws..
....aside.for.reassembly.
3).Remove.the.GFCI.from.the.weatherproof.Junction.Box.by.removing.the.(2).GFCI.mounting.screws.
REPLACE GFCI
1).Remove.the.wires,.one.at.a.time,.and.put.each.wire.in.the.matching.position.on.the.new.GFCI.
2).Place.the.newly.wired.GFCI.into.the.weatherproof.Junction.Box.and.secure.it.
3).Replace.the.cover.of.the.weatherproof.Junction.Box.using.the.(2).screws.previously.removed.
4).Turn.on.the.main.electrical.power.to.the.unit.and.retest.to.assure.proper.operation..Refer.to.TESTING.AND.
....OPERATION.on.page.7.