October 7, 2012
115-V 20-Amp 60-Hz Self-Timed Unit
14
MECHANICAL ASSEMBLIES
115-V 20-Amp 60-Hz Self-Timed Unit
Note:
Always turn off the power at the circuit breaker – place a lockout tag on the circuit breaker panel indicating that
the breaker is not to be turned on except by authorized personnel – and disconnect the electrical connections before
doing any work on the SUITMATE
®
unit. Simply turning off a switch is NOT enough. Use only proper tools, test equip-
ment, and work practices when servicing the SUITMATE
®
unit.
If there are questions concerning proper tools, equipment or practices, please call the factory for recommendations at:
(Telephone) 800-553-3353, (Fax) 847-742-3552 or (Email) [email protected].
Due to critical tolerances, use only specified replacement parts. (See the individual sections in this manual.)
Some disassembly and assembly procedures have not been included, as the procedures seem to be self-evident.
REMOVE SUITMATE
®
UNIT FROM THE WALL MOUNT BRACKET
Do This FIRST
prior to performing any electrical or mechanical maintenance.
•.Turn.off.the.main.electrical.power.to.the.unit.–.place.a.lockout.tag.on.the.circuit.breaker.panel.indicating.that.
...the.breaker.is.not.to.be.turned.on.except.by.authorized.personnel.–.and.disconnect.the.unit.before.doing.any.
...work.on.the.SUITMATE
®
.unit..Simply.turning.off.a.switch.is.NOT.enough.
•.Consult.the.individual.sections.in.this.manual.to.determine.the.exact.parts.and.fasteners.that.will.be.required.
...for.installation.of.mechanical.components.
CAUTION!
Make certain the main electrical power to the unit is turned off – and locked out
– before beginning work on the SUITMATE
®
unit.
EXTERNAL ELECTRICAL SERVICE
If.the.unit’s.electrical.service.is.coming.into.the.unit.from.outside.the.unit,.it.will.be.necessary.to.disconnect.the.
incoming.electrical.service.from.the.power.source..Prior.to.disconnecting.the.electrical.service.make.certain.
that.the.power.source.is.turned.off.and.locked.out!.Disconnect.the.incoming.liquid.tight.raceway.or.cable.from.
the.power.source.
EXTERNAL PLUMBING SERVICE
If.the.unit’s.plumbing.service.uses.the.factory.supplied.Drain.Hose.or.is.connected.from.outside.the.unit,.it.will.
be.necessary.to.disconnect.the.drain.hose.or.piping.from.its.external.hookup.
INTERNAL ELECTRICAL AND PLUMBING SERVICE
If.the.SUITMATE
®
.unit.was.installed.with.internally.connected.plumbing.and.electrical.connections:
1).Remove.the.cover.of.the.weatherproof.Junction.Box.that.contains.the.GFCI;.remove.the.GFCI;.disconnect.
....the.external.source.ground.wire.and.the.power.feed.lines.from.the.GFCI.terminals.marked.“Line”..Retain.the.
....weatherproof.Junction.Box.cover.and.fasteners.for.reinstallation.
2).Disconnect.the.power.feed.liquid.tight.raceway.or.cable.from.the.Junction.Box.and.the.internally.connected.
....drain.hose.
3).Remove.the.lower.fasteners.anchoring.the.unit.to.the.wall.
4).Remove.the.SUITMATE
®
.unit.from.the.Wall.Mount.Bracket.by.firmly.grasping.the.sides.of.the.Case.bottom
....and.gently.lifting.straight.up.until.the.unit.clears.the.upper.back.lip.of.the.Wall.Mount.Bracket..Take.the.
....SUITMATE
®
.unit.to.a.workbench.
REINSTALL THE SUITMATE
®
UNIT
CAUTION!
Make certain the main electrical power to the unit is turned off – and locked out
– before beginning work on the SUITMATE
®
unit.
Return.the.SUITMATE
®
.unit.to.its.proper.location.and.reconnect.the.unit.by.reversing.the.procedures.above.
Note:
Make certain the unit is level. If it is not level, remove the unit, adjust the Wall Mount Bracket and re-hang the
unit. A level installation is necessary to minimize vibration and insure proper drainage of wastewater.