background image

Airxcel Commercial Group Limited Product Warranty

If any part of your Airxcel Commercial Group Air Conditioner, Heat Pump or Unit Ventilator fails because of a manufacturing defect within the time 
frame in the table below, the Airxcel Commercial Group will furnish without charge, EXW Cordele, Georgia, the required replacement part. Any 
transportation, related service labor, diagnosis calls, filter, driers, and refrigerant are not included. The owner must provide proof of the date of the 
original start-up. The contractor’s invoice, the certificate of occupancy, or similar documents are examples of proof of the date of the original start-up.

Marvair, ICE, Eubank

Suburban Applied Products

90 Days DOA w/Flat Rate Labor

1 Year Parts/Labor – Flat Rate

1 Year Parts

5 Years Heat Exchanger

5 Years Compressor

5 Years Compressor

The following extra cost warranties are available from Airxcel Commercial Group:

Bronze

Silver

Gold

Diamond

Any Special Warranty Written for a Job

1 Year Parts/Labor

2 Years Parts/Labor

5 Years Parts/Labor

Any related service labor, diagnosis calls, filter, driers and refrigerant are not included. Airxcel Commercial Group will pay for non-priority shipping 
costs of the compressor during the first twelve months of the warranty period. After the first twelve months of the warranty period, all costs of 
shipment and risk of loss during the shipment of the compressor shall be the responsibility of the owner.

The owner of the product may ship the allegedly defective or malfunctioning product or part to Airxcel Commercial Group, at such owner’s expense, 
and Airxcel Commercial Group will diagnose the defect and, if the defect is covered under this warranty, Airxcel Commercial Group will honor its 
warranty and furnish the required replacement part. All costs for shipment and risk of loss during shipment of the product to Airxcel Commercial 
Group and back to the owner shall be the responsibility and liability of the owner. Upon written request by an owner, Airxcel Commercial Group 
may arrange for remote diagnosis of the allegedly defective or malfunctioning product or part but all costs for transportation, lodging and related 
expenses with regard to such diagnostic services shall be the responsibility and liability of the owner.

An owner requesting performance under this Warranty shall provide reasonable access to the allegedly defective or malfunctioning product or part 
to Airxcel Commercial Group and its authorized agents and employees.

This warranty applies only to products purchased and retained for use within the U.S.A., Canada, and Mexico.  This warranty does not cover 
damage caused by improper installation, misuse of equipment or negligent servicing.

THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PURCHASER OF AN AIRXCEL COMMERCIAL  GROUP HEAT PUMP 
OR AIR CONDITIONER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY 
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR USE, TO THE FULLEST EXTENT PERMITTED BY LAW.  IN NO EVENT 
SHALL ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR USE EXCEED THE TERMS OF THE APPLICABLE WARRANTY 
STATED ABOVE AND AIRXCEL COMMERCIAL GROUP SHALL HAVE NO OTHER OBLIGATION OR LIABILITY. IN NO EVENT SHALL MARVAIR 
BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OR MONETARY DAMAGES.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE-TO-
STATE.  Some states do not allow limitations or exclusions, so the above limitations and exclusions may not apply to you. 

09/2017 Rev.5

Supersedes 06/2004

IF YOU HAVE A PRODUCT PROBLEM

FIRST: 

Contact the installer of the equipment or the selling dealer for warranty service. You may find his name on the product or with your homeowners manual. 

If his name is not known, call your builder or general contractor if yours is a new structure.

SECOND: 

Contact the Suburban distributor who supplied the product to the installer/dealer.

THIRD: 

Contact:

 

Suburban Applied Products

 

Customer Service Department

 

156 Seedling Drive

 

Cordele, GA  31015

 

(229) 273-3636

 

Fax: (229) 273-5154

 www.SuburbanManufacturing.com

Please consult the Suburban Applied Products website at www.SuburbanManufacturing.com for the latest product literature. Detailed 

dimensional data is available upon request. A complete warranty statement can be found in each product’s Installation/Operation Manual, on 

our website. As part of the Suburban continuous improvement program, specifications are subject to change without notice.

P.O. Box 400  •  Cordele, GA 31010

156 Seedling Drive  •  Cordele, GA 31015 

Ph: 229-273-3636  •  Fax: 229-273-5154

Email: [email protected]

Manufactured by:

10

Содержание DYNAPACK S Series

Страница 1: ...the National Safe Transit Test This means that the packaged product with normal handling will withstand the load conditions encountered in normal transit and in handling Your unit should be inspected...

Страница 2: ...ack unit has been safety certified by Intertek Testing Services to comply with the national safety codes of the USA and Canada The Dynapack unit is certified to operate on natural or LP gas The Dynapa...

Страница 3: ...y out side or turned inside and routed to the building drain system If the wall sleeve drain is routed to the building sewer system then it must be trapped to prevent sewer gasses from escaping ELECTR...

Страница 4: ...is recommended that a 5 conductor thermostat wire be used in case the room thermostat needs power from the unit transformer The low voltage pigtails for the thermostat wiring must be routed to the ou...

Страница 5: ...at will call for heat and the combustion blower will begin to operate 6 The combustion blower will operate for 15 to 20 seconds before the ignition controls begins sparking then the gas valve will ope...

Страница 6: ...tion for both the USA and Canada Call Technical Service at 423 775 2131 for installations above 4500 feet OPERATION IN EXTREME COLD OR SNOWY AREAS In those areas where the ambient temperature is consi...

Страница 7: ...le Bronze Finish DYPA30AC1A and DYPA36AC1A 521051 LP Conversion Kit All Models 36 000 BTU input 48 000 BTU input 60 000 BTU input 1741 5 7 8 Wall Sleeve Kit DYPA12 DYPA18 and DYPA24 1736 5 7 8 Wall Sl...

Страница 8: ...G PK HUM FLAME 24V FLAME SWITCH BL O 230V INDUCER BK R OFM C BK BR WHT GAS VALVE SWITCH HIGH LIMIT ROLLOUT SWITCH SWITCH PRESSURE O BL PK PK R O G BL Y BL BL BL O NOTE 1 Y BK PK BL BL LIMIT BLOWER R O...

Страница 9: ...3m a D VERTICAL CLEARANCE TO VENTILATED SOFFIT LOCATED ABOVE THE TERMINAL WITHIN A HORIZONTAL DISTANCE OF 2 FEET 61cm FROM THE CENTER LINE OF THE TERMINAL a a M CLEARANCE UNDER VERANDA PORCH DECK OR B...

Страница 10: ...sponsibility and liability of the owner An owner requesting performance under this Warranty shall provide reasonable access to the allegedly defective or malfunctioning product or part to Airxcel Comm...

Страница 11: ...ng wires up to Top Line side of contactor 7 Wire as per drawing ES48000 sent with the kit to contactor ground lug 8 Re insert rubber drain hose through bushing with supplied Wires Heat cable 9 Insert...

Страница 12: ...iphon en T dans le tuyau de drainage en caoutchouc L utilisation d eau savonneuse peut faciliter l insertion 10 Alignez le siphon en P selon le besoin par rapport la plomberie de drainage existante 11...

Страница 13: ...n tel service seront assum s par le demandeur Un propri taire requ rant une intervention ce titre dans le cadre de la garantie devra permettre un acc s raisonnable au produit ou la pi ce incrimin e po...

Страница 14: ...ITU ES SUR DES PROPRI T S PUBLIQUES 7 PIEDS 2 13 cm a D ESPACE LIBRE LA VERTICALE PAR RAPPORT AU PAREMENT VENTIL SITU AU DESSUS DE LA SORTIE a a M ESPACE LIBRE SOUS LES V RANDAS LES PROCHES LES PATIOS...

Страница 15: ...L ALLUMEUR CC BK BK BK 24 VAC GROUND Y W C R G PK HUM FLAMME 24V FLAMME INTERRUPTEUR BL O 230V INDUCER BK R OFM C BK BR WHT VANNE GAZ FIN DE COURSE HAUTE PRESSOSTAT INTERRUPTEUR MISE EN APPLICATION O...

Страница 16: ...DYPA36AC1A 521051 Trousse de conversion au GPL tous les mod les Entr e de 36 000 BTU entr e de 48 000 BTU et entr e de 60 000 BTU 1741 Support mural de 5 7 8 po DYPA12 DYPA18 and DYPA24 1736 Support...

Страница 17: ...nt un but particulier et il ne faut pas les trafiquer en changeant leur emplacement ou par un c blage sp cial Si la fournaise ne fonctionne pas si le ventilateur de l air ambiant ne se met pas en marc...

Страница 18: ...z l appareil sous tension 3 Placez le thermostat de la pi ce en position de chauffage 4 Augmentez le r glage au dessus de la temp rature ambiante 5 Le thermostat demandera du chauffage et le ventilate...

Страница 19: ...de l appareil doit tre v rifi Ne d passez pas lb po ca de pression manom trique ou 14 po CE pour ce test autrement la vanne gaz pourrait tre endommag e MISE EN GARDE Suburban ne recommande pas d utili...

Страница 20: ...ou d entretien ALIMENTATION EN GAZ Tous les appareils Dynapack sont con us pour utiliser du gaz naturel L appareil doit tre converti au GPL l aide la trousse de conversion du fabricant si l appareil d...

Страница 21: ...ons pr sent es dans ce manuel Les appareils Dynapack sont des ensembles verticaux contenant un chauffage au gaz et une climatisation l lectricit Les appareils Dynapack sont certifi s au plan de la s c...

Страница 22: ...stall uniquement l aide des accessoires approuv s grille d ext rieur et manchons muraux Le non respect de ces instructions peut entra ner des dommages mat riels des blessures et m me la mort MISE EN G...