Pilot lamp / Video mode (Fusion)

The installed pilot lamp allows a better orientation during a night dive. Similarly this LED 
illuminate the object for autofocus and the cameradisplay .
To start the pilot lamp push the pilot button on the rear of your flash. 

Pro160

: to switch off the lamp push the button again.

Fusion 

to change from pilot to video mode, push the button again. the fusion changes 

from approx. 20% to 100% lightning power .
During the video mode the flash function is not available, this feature allows you to use the 
lamp also for photos with ambient light and lamp.
To change back in flash mode push the pilot button again.

automatic TTL mode on analogue cameras

 

The flash identifies in 

AUTO

- mode the connected camera system  automatically.

(Nikon, Canon, Pentax. analogue )
The ttl-sensor is mounted in the camera and gives a switch-off pulse to the flash if the 
exposure is OK.

For the correctness of the exposure is now the camera responsible, as the 
delivered   light   achievement   is   determined   by   the   camera.   Therefore 
manipulations of the exposure can in this mode of operation only be made at 
the camera. 

As soon as the flash is connected with a analogical camera, the ready symbol in the 
camera lights up after touching the trigger lightly. 
Strongly reflecting objects as well as back light photographs nearly always lead to under 
exposure in the TTL mode. Use for this cases the manual mode or correct the exposure 
index adjuster of the camera in positives (+). Do not forget resetting after shooting. 
The same problem you have when using extreme wide angle objectives, if relative small 
object is in front of a dark background. The sensor recognizes in this case mainly the dark 
background and turns-off the flashlight to late.  Overexposures results.

    

operating range on TTL-mode

According to the selected aperture arises the operating range, which  depends also  on 
the turbidity under water.
The best aperture in the different situations depends on the needed reach and the depth 
of   sharpness.  With   smaller   becoming   f   number   (larger   opening)   the   depth   sharpness 
range is reduced. Use a small f-number, where the background is to be illustrated in a dif­
fuse way. for Macro shoots normally higher f-numbers were used. 
For standard situations a midrange aperture, f.e. aperture 5,6 to 8 is recommended. The 
operating range in this case is approx. 2 meters (6,5 feet)  which might be sufficient for 
most UW photographs. 

6

Содержание Pro 160 Fusion

Страница 1: ...3 2010 1 user manual user manual...

Страница 2: ...ER STEPS 8 PROTECTION AND CARE 9 CABLE CONNECTIONS 10 FLASH ARM CONNECTOR 10 FORM UP THE FLASH CAPACITOR 11 TTL CHECK 11 LEAKAGE ON THE HOUSING 11 SAFETY INSTRUCTIONS 12 IMPORTANT NOTES FOR DIVING TRI...

Страница 3: ...rsion TTL analog Ixx I TTL Exx E TTL Oxx Olympus version TTL analogue Ixx I TTL Exx E TTL Oxx Olympus ready lamp mode switch pilot push button accu connector synchronous connector ready lamp mode swit...

Страница 4: ...weight They have no MEMORY effect The accumulator haven t need to be unloaded before charging insert the S4 connector from the charger in the connector from the external accumulator system Please cons...

Страница 5: ...f the unit always before you connect or disconnect accu tank deep charge protection In the case of falling voltage below working voltage the electronic switches off the pilot lamp and or the flash Thu...

Страница 6: ...mera As soon as the flash is connected with a analogical camera the ready symbol in the camera lights up after touching the trigger lightly Strongly reflecting objects as well as back light photograph...

Страница 7: ...unction a digital converter is absolutely necessary Depends on the underwater housing manufacturer or model the converter is already integrated to the camera housing Please ask therefore your the manu...

Страница 8: ...r your camera supports manual flashes functionality the flash delivers in manual mode a constant lightning energy These power steps are controlled by the integrated computer and therefore every time i...

Страница 9: ...ing water can arrive at the socketcontacts The sockets are inward sealed so that no water can arrive in the flash appartus even if the cables are not correctly fastened Make sure that the locknut of t...

Страница 10: ...tive cable or defective connectors water can break in the system NEVER DIP THE UNITS WITHOUT CAPS OR MOUNTED CABLES INTO THE WATER flash arm connector The flash arm connector on the bottom side of the...

Страница 11: ...leakage on the housing If water penetrates into the flash gun body please follow the instructions below Switch off the device Remove the rear cap ring this ring doesn t have a sealing function but is...

Страница 12: ...by untrained technicians Do not open the flash gun There is a risk of leakage if the device is reassembled incorrectly The electronics will be destroyed immediately if salt water penetrates into the...

Страница 13: ...mage Pack the device in a robust cardboard box with plenty of room on all sides for padding material Do not use a shoe box Detach the flash gun arm covers and other removable parts from your device Pl...

Страница 14: ...version automatic camera identification for NIKON CANON PENTAX TTL mode digital only digital version by internal converter or as analogue model by external converter preflashes max 20 kHz ready lamp...

Страница 15: ...digital version by internal converter or as analogue model by external converter preflashes max 20 kHz ready lamp by LED yes slave mode external trigger unit optional pilot lamp 3 area LED modules in...

Страница 16: ...l defect shall either be repaired free of charge or replaced should the repair costs be disproportionately high A more extensive liability is excluded subtronic shall not be liable for indirect damage...

Страница 17: ...dress Model Serial number contents of parcel Charger Accu Synccord caps quantity______ others ______________________ Error description normally we need 14 days for standard repairs For repairs which m...

Страница 18: ...ess Office Mo Fr 9 00 12 00 and 13 00 16 00 Tel 0049 0 7023 74669 0 Fax 16 E mail service subtronic de visit us in Internet http www subtronic de 18 Michael Becker Strasse 9A D 73235 Weilheim Deutschl...

Страница 19: ...dress Model Serial number contents of parcel Charger Accu Synccord caps quantity______ others ______________________ Error description normally we need 14 days for standard repairs For repairs which m...

Страница 20: ...d 13 00 16 00 Tel 0049 0 7023 74669 0 Fax 16 Email service subtronic de visit us in Internet http www subtronic de Your Subtronic Dealer serial number date of delivery 20 Michael Becker Strasse 9A D 7...

Отзывы: