SAFETY INSTRUCTIONS

The flash gun is designed and only approved for photographic use.

The device may in no case be used in the vicinity of inflammable gases or liquids. 
RISK OF EXPLOSION!

Never trigger a flash in the immediate vicinity of the eyes! Triggering of flashes 
directly in front of the eyes of people or animals may cause damages to the retina 
and serious sight impairment or blindness.

Use only the supplied charger, which is specially designed for compatibility with the 
accumulators used in the flash gun.

Do not expose the accumulators to excessive heat such as sunlight, fire or similar 
heat sources.

No opaque material may be positioned immediately before, or directly on the dome 
port when triggering the flash. The high energy level of the flash could lead to burn 
or to deformation of the dome port.

Do not dismantle the flash gun. HIGH VOLTAGE! DANGER TO LIFE! The body 
does not contain any parts that can be repaired by untrained technicians.

Do not open the flash gun. There is a risk of leakage if the device is reassembled 
incorrectly. The electronics will be destroyed immediately if salt water penetrates 
into the housing.

There is a risk of overloading the electronics and the accumulator when taking 
consequential pictures with the flash. Take a break after using the flash approx. 20 
times.

As   a   consumer   you   are   legally   obliged   to   return   used   accumulators.   We   will 
dispose of your flash gun free of charge.

important notes for diving trips

Test the device in good time (6 weeks) before going on holiday.

Check the cable.

A spare cable has saved many a photography holiday.

Pack the device in your hand luggage.

Wrap the cable in a towel.

Check the flash arm. Lightly lubricate the grip levers.

Regularly rinse the device in fresh water.

When you return from holiday, take the device into an indoor pool to dissolve 
any residual salt crystals under pressure.

When you have been using the device for a few years, treat it to a check-up at 
subtronic as the O-rings will not live forever and at some point the 
accumulator will give up the ghost, as well.

12

Содержание Pro 160 Fusion

Страница 1: ...3 2010 1 user manual user manual...

Страница 2: ...ER STEPS 8 PROTECTION AND CARE 9 CABLE CONNECTIONS 10 FLASH ARM CONNECTOR 10 FORM UP THE FLASH CAPACITOR 11 TTL CHECK 11 LEAKAGE ON THE HOUSING 11 SAFETY INSTRUCTIONS 12 IMPORTANT NOTES FOR DIVING TRI...

Страница 3: ...rsion TTL analog Ixx I TTL Exx E TTL Oxx Olympus version TTL analogue Ixx I TTL Exx E TTL Oxx Olympus ready lamp mode switch pilot push button accu connector synchronous connector ready lamp mode swit...

Страница 4: ...weight They have no MEMORY effect The accumulator haven t need to be unloaded before charging insert the S4 connector from the charger in the connector from the external accumulator system Please cons...

Страница 5: ...f the unit always before you connect or disconnect accu tank deep charge protection In the case of falling voltage below working voltage the electronic switches off the pilot lamp and or the flash Thu...

Страница 6: ...mera As soon as the flash is connected with a analogical camera the ready symbol in the camera lights up after touching the trigger lightly Strongly reflecting objects as well as back light photograph...

Страница 7: ...unction a digital converter is absolutely necessary Depends on the underwater housing manufacturer or model the converter is already integrated to the camera housing Please ask therefore your the manu...

Страница 8: ...r your camera supports manual flashes functionality the flash delivers in manual mode a constant lightning energy These power steps are controlled by the integrated computer and therefore every time i...

Страница 9: ...ing water can arrive at the socketcontacts The sockets are inward sealed so that no water can arrive in the flash appartus even if the cables are not correctly fastened Make sure that the locknut of t...

Страница 10: ...tive cable or defective connectors water can break in the system NEVER DIP THE UNITS WITHOUT CAPS OR MOUNTED CABLES INTO THE WATER flash arm connector The flash arm connector on the bottom side of the...

Страница 11: ...leakage on the housing If water penetrates into the flash gun body please follow the instructions below Switch off the device Remove the rear cap ring this ring doesn t have a sealing function but is...

Страница 12: ...by untrained technicians Do not open the flash gun There is a risk of leakage if the device is reassembled incorrectly The electronics will be destroyed immediately if salt water penetrates into the...

Страница 13: ...mage Pack the device in a robust cardboard box with plenty of room on all sides for padding material Do not use a shoe box Detach the flash gun arm covers and other removable parts from your device Pl...

Страница 14: ...version automatic camera identification for NIKON CANON PENTAX TTL mode digital only digital version by internal converter or as analogue model by external converter preflashes max 20 kHz ready lamp...

Страница 15: ...digital version by internal converter or as analogue model by external converter preflashes max 20 kHz ready lamp by LED yes slave mode external trigger unit optional pilot lamp 3 area LED modules in...

Страница 16: ...l defect shall either be repaired free of charge or replaced should the repair costs be disproportionately high A more extensive liability is excluded subtronic shall not be liable for indirect damage...

Страница 17: ...dress Model Serial number contents of parcel Charger Accu Synccord caps quantity______ others ______________________ Error description normally we need 14 days for standard repairs For repairs which m...

Страница 18: ...ess Office Mo Fr 9 00 12 00 and 13 00 16 00 Tel 0049 0 7023 74669 0 Fax 16 E mail service subtronic de visit us in Internet http www subtronic de 18 Michael Becker Strasse 9A D 73235 Weilheim Deutschl...

Страница 19: ...dress Model Serial number contents of parcel Charger Accu Synccord caps quantity______ others ______________________ Error description normally we need 14 days for standard repairs For repairs which m...

Страница 20: ...d 13 00 16 00 Tel 0049 0 7023 74669 0 Fax 16 Email service subtronic de visit us in Internet http www subtronic de Your Subtronic Dealer serial number date of delivery 20 Michael Becker Strasse 9A D 7...

Отзывы: