Page 24
Cooktop Electric (CE) Series
Cooktop Electric (CE) Series
Troubleshooting
4-6
#826496 - Revision A - May, 2015
Cooking Zone Specific Errors
Code
Description
Test
Action
E5
E6
E7
E8
EA
Relay error
Power supply error
Unspecified error
(usually accompanied by
another error)
Fan error
Controller error
None
1. Inspect all power supply
connections.
2. Test L1 to Ground
3. Test L2 to Ground
4. Test L1 to L2
5. Test cooktop cabinet to
adjacent ground receptacle
None
Test fan - See page 4-8
None
1. Cycle unit power
2. Replace power board.
1. L1 to Ground and L2 to Ground
between 90 VAC and 132 VAC.
2. L1 to L2 between 180 VAC and
265 VAC.
3. Resistance to ground should be
close to zero ohms.
4. Report issue to consumer.
1. Cycle unit power.
1. Test fan operation.
2. Ensure fan vent is not blocked.
3. Replace power board.
1. Cycle unit power.
2. Replace control board.