Cooktop Electric (CE) Series
Cooktop Electric (CE) Series
2-9
#826496 - Revision A - May, 2015
Diagnostic Mode
Used to test the cooktop systems, view stored error codes, view real-time readings from system sensors, and to
enter/exit Showroom mode. Individual element assembly temperature readings are not available for CE models.
Entering Diagnostic Mode:
Must be entered from Lock Mode.
•
Touch and hold the
“+”
pad and
“-”
pad for 5 seconds.
•
After 5 seconds enters LED test, alerting the user to remove their fingers.
•
If another key pad sensor detects a signal, Diagnostic Mode does not engage.
•
If either the
“+”
or
“-”
pad is not released after 7 seconds, Diagnostic Mode does not engage.
•
Power to all element assemblies is disabled.
•
After 60 seconds if no input is detected the control returns to Lock Mode.
•
ALL OFF
pad exits Diagnostic Mode and the control returns to Lock Mode.
•
There are no audible signals.
•
To step through the various tests touch the
“+”
and
“-”
pads.
•
Rear left
“…”
display advances one LED for each test to identify which test is being performed.
•
Diagnostic Mode Procedures
a.
LED Test:
All LED indicators for all control zones are on.
LOCK
LED, all segments of the Timer display, and
HOT
•
displayed.
Front left control zone
SIM/MLT
,
“…”
or
HI
pads cycles LEDs to on, dim, or off.
•
One
“.”
displayed on the left rear control zone indicates LED test is running.
•
“+”
pad engages Generator Reconfiguration.
•
b.
Generator Reconfiguration:
This mode is present but shows 00 as it is not active on CE models.
•
c.
Control Temperature Readout:
Touch
“+”
pad during Generator Reconfiguration.
•
Three
“.”
are displayed on left rear control zone.
•
2-digit display shows the ambient control temperature in °C.
•
Over 99° C (210° F), the decimal point of the 2 digit display turns on to indicate the temperature is 100°
•
C or higher.
“-”
pad engages Generator Reconfiguration.
•
“+”
pad engages Heat Sink Temperature.
•
d.
Heat Sink Temperature Test:
Touch “+” pad during the Control Temperature Readout.
•
Four “.” are displayed on the left rear control zone.
•
2-digit display shows 00. There is no state on CE models.
•
e.
Element Temperature Test
This mode is present but shows 00 as it is not active on CE models.
•