Page 21
Troubleshooting
Cooktop Electric (CE) Series
Cooktop Electric (CE) Series
4-3
#826496 - Revision A.1 - April, 2017
Diagnostic Mode
Used to test the cooktop systems, view stored error codes, and to enter/exit Showroom mode.
Entering Diagnostic Mode
Enter Lock Mode.
1.
Touch and hold the
“+”
pad and
“-”
pad for 5 seconds.
2.
After 5 seconds enters LED test, alerting the user to remove their fingers.
•
If another key pad sensor detects a signal, Diagnostic Mode does not engage.
•
If either the
“+”
or
“-”
pad is not released after 7 seconds, Diagnostic Mode does not engage.
•
Power to all element assemblies is disabled.
•
After 60 seconds if no input is detected the control returns to Lock Mode.
•
ALL OFF
pad exits Diagnostic Mode and the control returns to Lock Mode.
•
There are no audible signals.
•
To step through the various tests touch the
“+”
and
“-”
pads.
3.
Rear left
“…”
display advances one LED for each test to identify which test is being performed.
•
Diagnostic Mode Procedures
LED Test
Front left control zone
SIM/MLT
,
“…”
or
HI
pads cycles LEDs to on, dim, or off.
1.
All LED indicators for all control zones are on.
LOCK
LED, all segments of the Timer display,
HOT
dis-
•
play are on.
One
“.”
displayed on the left rear control zone indicates LED test is running.
•
“+”
pad engages Generator Reconfiguration.
2.
Generator Reconfiguration
Touch
“+”
pad during the LED Test.
1.
Two
“.”
displayed on left rear control zone.
•
2-digit display shows CF, but is not active on CE models.
•
“-”
pad returns to LED Test and
“+”
pad advances to Control Temperature Readout.
2.
Control Temperature Readout
Touch
“+”
pad during Generator Reconfiguration.
1.
Three
“.”
displayed on left rear control zone.
•
2-digit display shows the ambient control temperature in °C.
•
Over 99° C (210° F), the decimal point of the 2 digit display turns on to indicate the temperature is 100°
•
C or higher.
Front left control zone
SIM/MLT
and
HI
pads cycles between the two temperature readouts of the control
•
board.
“-”
pad returns to Generator Reconfiguration and
“+”
pad advances to Heat Sink Temperature Test.
2.
Heat Sink Temperature Test
Touch
“+”
pad during the Control Temperature Readout.
1.
Four
“.”
displayed on left rear control zone.
•
2-digit display shows 0, but is not active on CE models.
•
“-”
pad returns to Control Temperature Readout and
“+”
pad advances to Element Temperature Test.
2.