41
-
© STULZ GmbH, Hamburg
-
41
-
Tab. 8.3.3
b1
DE-
HUMIDIFICATION
REQUEST
DILUTION DRAIN
WITH
CONTACTOR ...
DRAIN WHEN NEW
DEMAND <= 2/3
CURRENT DEMAND
(CONTACTOR OPENED)
TOTAL DRAIN
FOR
INACTIVITY
DISPLAY OF
WARNINGS
“CL” & “CP
ALARM RELAY
ACTIVATED
WHEN ...
TOTAL
PERIODICAL
DRAIN
42
OFF
CLOSED
YES
OFF
ON
ALARMS ABSENT
OFF
43
ON
CLOSED
YES
OFF
ON
ALARMS ABSENT
OFF
44
OFF
OPEN
NO
OFF
ON
ALARMS ABSENT
OFF
45
ON
OPEN
NO
OFF
ON
ALARMS ABSENT
OFF
46
OFF
CLOSED
NO
OFF
ON
ALARMS ABSENT
OFF
47
ON
CLOSED
NO
OFF
ON
ALARMS ABSENT
OFF
48
OFF
OPEN
YES
ON, depending on bF
OFF
ALARMS ABSENT
OFF
49
ON
OPEN
YES
ON, depending on bF
OFF
ALARMS ABSENT
OFF
50
OFF
CLOSED
YES
ON, depending on bF
OFF
ALARMS ABSENT
OFF
51
ON
CLOSED
YES
ON, depending on bF
OFF
ALARMS ABSENT
OFF
52
OFF
OPEN
NO
ON, depending on bF
OFF
ALARMS ABSENT
OFF
53
ON
OPEN
NO
ON, depending on bF
OFF
ALARMS ABSENT
OFF
54
OFF
CLOSED
NO
ON, depending on bF
OFF
ALARMS ABSENT
OFF
55
ON
CLOSED
NO
ON, depending on bF
OFF
ALARMS ABSENT
OFF
56
OFF
OPEN
YES
OFF
OFF
ALARMS ABSENT
OFF
57
ON
OPEN
YES
OFF
OFF
ALARMS ABSENT
OFF
58
OFF
CLOSED
YES
OFF
OFF
ALARMS ABSENT
OFF
59
ON
CLOSED
YES
OFF
OFF
ALARMS ABSENT
OFF
60
OFF
OPEN
NO
OFF
OFF
ALARMS ABSENT
OFF
61
ON
OPEN
NO
OFF
OFF
ALARMS ABSENT
OFF
62
OFF
CLOSED
NO
OFF
OFF
ALARMS ABSENT
OFF
63
ON
CLOSED
NO
OFF
OFF
ALARMS ABSENT
OFF
64
OFF
OPEN
YES
ON, depending on bF
ON
ALARMS PRESENT
ON, depending on bE
65
ON
OPEN
YES
ON, depending on bF
ON
ALARMS PRESENT
ON, depending on bE
66
OFF
CLOSED
YES
ON, depending on bF
ON
ALARMS PRESENT
ON, depending on bE
67
ON
CLOSED
YES
ON, depending on bF
ON
ALARMS PRESENT
ON, depending on bE
68
OFF
OPEN
NO
ON, depending on bF
ON
ALARMS PRESENT
ON, depending on bE
69
ON
OPEN
NO
ON, depending on bF
ON
ALARMS PRESENT
ON, depending on bE
70
OFF
CLOSED
NO
ON, depending on bF
ON
ALARMS PRESENT
ON, depending on bE
71
ON
CLOSED
NO
ON, depending on bF
ON
ALARMS PRESENT
ON, depending on bE
72
OFF
OPEN
YES
OFF
ON
ALARMS PRESENT
ON, depending on bE
73
ON
OPEN
YES
OFF
ON
ALARMS PRESENT
ON, depending on bE
74
OFF
CLOSED
YES
OFF
ON
ALARMS PRESENT
ON, depending on bE
75
ON
CLOSED
YES
OFF
ON
ALARMS PRESENT
ON, depending on bE
76
OFF
OPEN
NO
OFF
ON
ALARMS PRESENT
ON, depending on bE
77
ON
OPEN
NO
OFF
ON
ALARMS PRESENT
ON, depending on bE
78
OFF
CLOSED
NO
OFF
ON
ALARMS PRESENT
ON, depending on bE
79
ON
CLOSED
NO
OFF
ON
ALARMS PRESENT
ON, depending on bE
80
OFF
OPEN
YES
ON, depending on bF
OFF
ALARMS PRESENT
ON, depending on bE
81
ON
OPEN
YES
ON, depending on bF
OFF
ALARMS PRESENT
ON, depending on bE
82
OFF
CLOSED
YES
ON, depending on bF
OFF
ALARMS PRESENT
ON, depending on bE
83
ON
CLOSED
YES
ON, depending on bF
OFF
ALARMS PRESENT
ON, depending on bE
84
OFF
OPEN
NO
ON, depending on bF
OFF
ALARMS PRESENT
ON, depending on bE
85
ON
OPEN
NO
ON, depending on bF
OFF
ALARMS PRESENT
ON, depending on bE
86
OFF
CLOSED
NO
ON, depending on bF
OFF
ALARMS PRESENT
ON, depending on bE
87
ON
CLOSED
NO
ON, depending on bF
OFF
ALARMS PRESENT
ON, depending on bE
88
OFF
OPEN
YES
OFF
OFF
ALARMS PRESENT
ON, depending on bE
89
ON
OPEN
YES
OFF
OFF
ALARMS PRESENT
ON, depending on bE
90
OFF
CLOSED
YES
OFF
OFF
ALARMS PRESENT
ON, depending on bE
91
ON
CLOSED
YES
OFF
OFF
ALARMS PRESENT
ON, depending on bE
92
OFF
OPEN
NO
OFF
OFF
ALARMS PRESENT
ON, depending on bE
93
ON
OPEN
NO
OFF
OFF
ALARMS PRESENT
ON, depending on bE
94
OFF
CLOSED
NO
OFF
OFF
ALARMS PRESENT
ON, depending on bE
95
ON
CLOSED
NO
OFF
OFF
ALARMS PRESENT
ON, depending on bE
96
OFF
OPEN
YES
ON, depending on bF
ON
ALARMS ABSENT
ON, depending on bE
97
ON
OPEN
YES
ON, depending on bF
ON
ALARMS ABSENT
ON, depending on bE
98
OFF
CLOSED
YES
ON, depending on bF
ON
ALARMS ABSENT
ON, depending on bE
99
ON
CLOSED
YES
ON, depending on bF
ON
ALARMS ABSENT
ON, depending on bE
100
OFF
OPEN
NO
ON, depending on bF
ON
ALARMS ABSENT
ON, depending on bE
101
ON
OPEN
NO
ON, depending on bF
ON
ALARMS ABSENT
ON, depending on bE
102
OFF
CLOSED
NO
ON, depending on bF
ON
ALARMS ABSENT
ON, depending on bE
103
ON
CLOSED
NO
ON, depending on bF
ON
ALARMS ABSENT
ON, depending on bE
104
OFF
OPEN
YES
OFF
ON
ALARMS ABSENT
ON, depending on bE
105
ON
OPEN
YES
OFF
ON
ALARMS ABSENT
ON, depending on bE
106
OFF
CLOSED
YES
OFF
ON
ALARMS ABSENT
ON, depending on bE
107
ON
CLOSED
YES
OFF
ON
ALARMS ABSENT
ON, depending on bE
108
OFF
OPEN
NO
OFF
ON
ALARMS ABSENT
ON, depending on bE
109
ON
OPEN
NO
OFF
ON
ALARMS ABSENT
ON, depending on bE
110
OFF
CLOSED
NO
OFF
ON
ALARMS ABSENT
ON, depending on bE
111
ON
CLOSED
NO
OFF
ON
ALARMS ABSENT
ON, depending on bE
112
OFF
OPEN
YES
ON, depending on bF
OFF
ALARMS ABSENT
ON, depending on bE
113
ON
OPEN
YES
ON, depending on bF
OFF
ALARMS ABSENT
ON, depending on bE
114
OFF
CLOSED
YES
ON, depending on bF
OFF
ALARMS ABSENT
ON, depending on bE
115
ON
CLOSED
YES
ON, depending on bF
OFF
ALARMS ABSENT
ON, depending on bE
116
OFF
OPEN
NO
ON, depending on bF
OFF
ALARMS ABSENT
ON, depending on bE
117
ON
OPEN
NO
ON, depending on bF
OFF
ALARMS ABSENT
ON, depending on bE
118
OFF
CLOSED
NO
ON, depending on bF
OFF
ALARMS ABSENT
ON, depending on bE
119
ON
CLOSED
NO
ON, depending on bF
OFF
ALARMS ABSENT
ON, depending on bE
120
OFF
OPEN
YES
OFF
OFF
ALARMS ABSENT
ON, depending on bE
121
ON
OPEN
YES
OFF
OFF
ALARMS ABSENT
ON, depending on bE
122
OFF
CLOSED
YES
OFF
OFF
ALARMS ABSENT
ON, depending on bE
123
ON
CLOSED
YES
OFF
OFF
ALARMS ABSENT
ON, depending on bE
124
OFF
OPEN
NO
OFF
OFF
ALARMS ABSENT
ON, depending on bE
125
ON
OPEN
NO
OFF
OFF
ALARMS ABSENT
ON, depending on bE
126
OFF
CLOSED
NO
OFF
OFF
ALARMS ABSENT
ON, depending on bE
127
ON
CLOSED
NO
OFF
OFF
ALARMS ABSENT
ON, depending on bE