Model 5402 User Guide
Issue 3, August 2021
Studio Technologies, Inc.
Page 53
Model 5402
DANTE LEADER CLOCK WITH GNSS SYNCHRONIZATION
Appendix G–Accessing the Unit when the User Name and/
or Password
are
Not Known
Follow this procedure to access the Configuration menu webpages if the user name and/or password is not known.
1. Remove power from the Model 5402.
2. Press and hold the left arrow and Enter buttons.
3. While continuing to hold the two buttons apply AC Mains or 12 volts DC power.
4. Continue to hold the two buttons and allow the Model 5402 to start. The Status LEDs on the front panel will first light
green then light red in their start-up sequence.
5. Once the Status LEDs have completed their start-up sequence release the two buttons.
6. Use a web browser to access the Model 5402’s Configuration menu webpages. The management port’s IP address
to use is shown in the current management IP address page on the front-panel display. Pressing the Enter button
will cause the current management IP address page to immediately show on the front-panel display.
7. From the Home webpage select the Login webpage tab. Leave the user name and password fields empty and click
the Log In button. This will allow access to the Configuration menu selections. At this point your web browser should
display the Model 5402’s Home webpage.
8. Navigate to the Access menu. From this webpage you will be able to view the stored user name. You will not be
able to view the previously saved password. Enter and confirm a new password. Henceforth, to access the Model
5402’s Configuration menu will require the use of the stored user name and password.