Model 5402
DANTE LEADER CLOCK WITH GNSS SYNCHRONIZATION
Network Menu
Interfaces
There are twelve display-only fields that relate to the key
parameters that are associated with the Dante and man-
agement interfaces. For clarity they display in the form of
a simple table.
IP Addresses:
These three display-only fields will show
the current IP addresses associated with the Model 5402’s
Dante primary, Dante secondary, and management ports.
The Dante primary and management fields will show either
Link Down or an IP address. The Dante secondary field will
show Disabled, Link Down, or an IP address. Link down
will display if an Ethernet connection has not been made to
the appropriate RJ45 jack on the Model 5402’s back panel.
Disabled will show if Dante redundancy has not been en-
abled in the Dante Controller application. The 32-bit IP v4
addresses will be displayed in what’s known as dot-decimal
notation (4 octets, each separated by a dot).
How the IP addresses are assigned will depend on the
Model 5402’s network configuration setting as performed
using the Dante Controller application. Each IP address
can be established automatically using a DHCP server or
the IPv4 link-local protocol. An IP address assigned to the
Dante primary interface by link-local will have a format of
169.254.x.x. An IP address assigned to the Dante second-
ary interface by link-local will have a format of 172.31.x.x.
The Dante primary and secondary IP addresses can also
be individually set to a manual (static or fixed) IP addresses
using the Dante Controller application.
If the network configuration is selected for switched the
Dante primary IP address will be associated with a network
connection made to either the Dante primary or Dante
secondary RJ45 jacks on the Model 5402’s back panel.
Link down will display if no connection is present. The IP
address for the Dante secondary interface will show dis-
abled as it is not being utilized in this network mode. The
management IP address will be associated with a network
connection made to the management RJ45 jack on the
Model 5402’s back panel.
If the network configuration is selected for Redundant then
the Dante primary IP address will be associated with the
RJ45 jack labeled PRI on the Model 5402’s back panel.
Link Down will display if a valid Ethernet connection has
not been made to the Dante primary Ethernet interface.
The Dante secondary IP address will be associated with
the RJ45 jack labeled SEC on the Model 5402’s back panel.
Link Down will display if a valid Ethernet connection has not
been made with the Dante secondary Ethernet interface.
The management IP address with be associated with a
network connection made to the RJ45 jack labeled MGMT
on the Model 5402’s back panel.
If the network configuration is selected in Dante Controller
for SMgmt then the Dante primary IP address will
be associated with a network connection made to either
the Dante primary or the Dante secondary RJ45 jacks on
the Model 5402’s back panel. The IP address field for the
Dante secondary interface will show Disabled as it is not
Содержание Dante 5402