-9 -
Pump Connections (General)
The pump should not be screwed down, ensure anti-vibration feet and flexible
hoses are used.
½ " Inline Strainer
(Not supplied)
15 mm Flexible pipe with push-in
connections, always ensure
connection is fully pushed home and
that hoses are kept as straight as
possible. Do not kink or twist the
hose.
In the case of horizontal feeds use a
15 mm John Guest stem elbow. Do
not bend hose more than 30° as they
may become damaged, transmit
noise or leak.
22 mm Outlet Pipework
to shower/bathroom
22 x 15 mm Reducer
15 mm Isolating
valve to allow easy
pump service.
(Not supplied)
Flow Switch
Control
Pump Head
Induction Motor
Anti-vibration rubber
feet
The hose connection
nuts on the inlets and
outlets of the pump
should not be removed.
½ " x 15 mm
Compression fitting
Hexagonal cap (removal
allows access to filter
gauze)
½ " x 15 mm
Compression
fitting
22 x 15 mm
Reducer
22 mm Inlet Pipework fed
from water storage
system.
Fig.13 (Pump connection variants)
Single
Twin
Fig.12
Twin
Outlet
Outlet
Outlet
Inlet
Inlet
Inlet