Wiring of connection unit
WARNING: This appliance must be earthed.
The wires in the mains lead (supply cord) are coloured in accordance with the following
code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead of this appliance may not correspond with
the coloured markings identifying the terminals in your connection unit proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the
connection unit which is marked with the letter E or by the earth symbol:
or coloured
green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with
the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter L or coloured red.
Wiring Diagrams
The supply cord and internal wiring within the terminal box are routed
and secured to ensure compliance with the electrical standard
EN60335-1. It is essential that any disturbance of this internal wiring is
avoided and the factory routing and securing of all internal wiring is
always maintained.
Parallel wiring of two single pumps.
Due to constant development of pump control circuitry, specific
approval must be obtained from Stuart Turner Ltd to confirm electrical
compatibility between any two pumps when being wired in parallel.
Failure to adhere may result in component damage and invalidate
guarantee.
-11 -
FLOWSWITCH
REED (S2)
GREEN / YELLOW
BLUE
BROWN
L
LOAD
N
S2 S2
L
E
N
S1
S1
MAIN WINDING
THERMOTRIP
CAPACITOR
START WINDING
BLUE
BROWN
BLA
CK
RED
BLUE
BROWN
230 VAC/1PH/50Hz
SUPPLY
Single Pumps
Fig. 15
Содержание Showermate 1.5 bar Single
Страница 19: ...19 NOTES...