- 14 -
c)
Any tap or control valve within the system when opened and closed will now turn
the pump on/off. Check system for leaks, if clear the system is now operating
correctly.
d)
Carefully check pump and pipework for leaks whilst pump running and stationary
before leaving the installation unattended.
For Further Technical Support
Phone the Stuart Turner support line on 01491 572655. Our staff are trained to help
and advise you over the phone or arrange for a service engineer to call.
MAINTENANCE
WARNINGS:
Care should be taken to protect pump from frost and freezing,
particularly when located in loft position.
Pump Location
If possible site the pump in a location where in the unlikely event of a
water leak, any spillage is contained or routed to avoid electrics or
areas sensitive to water damage.
1. No routine maintenance is required, but provision should be made
for easy access to the pump to allow repairs due to normal wear and
tear.
2. Disconnect electrical supply before working on pump.
3.
Turn off water supplies to the pump and release pressure by opening water outlets
before attempting maintenance.
4.
When the installation is fitted with inline strainers (not supplied with kit), these may
require periodical cleaning. The frequency of this operation is dependent upon
installation conditions.
The strainer is located in the inlet pipework to the pump (see pump connection
section). The gauze filter is removed as follows:-
a)
Isolate pump electrically.
b)
Release all system pressure.
c)
Isolate water supply.
d)
Remove screwed hexagonal plug from strainer body (see pump connection
section).
e)
Remove and clean stainless steel gauze filter.
f)
Re-assemble gauze and secure plug tightly.
g)
After maintenance is completed, refer to commissioning section for instructions
on re-starting pump.
5.
As water is heated scale deposits are released in areas of hard water (usually south
of a line between the Wash and Bristol Channel), scale can cause the mechanical
seal to stick if left without use for long periods. We recommend the pump is run for at
least 5 minutes every four weeks to “exercise” all working parts. Run on cool water.
See technical specification for note on water temperature. This particularly applies to
guest bathrooms used infrequently.
Cont....