Stuart Turner Showermate 1.5 bar Single Скачать руководство пользователя страница 14

- 14 -

c)

Any tap or control valve within the system when opened and closed will now turn 
the pump on/off.  Check system for leaks, if clear the system is now operating 
correctly.

d)

Carefully check pump and pipework for leaks whilst pump running and stationary 
before leaving the installation unattended.

For Further Technical Support

Phone the Stuart Turner support line on 01491 572655.  Our staff are trained to help

and advise you over the phone or arrange for a service engineer to call.

MAINTENANCE

WARNINGS:

Care should be taken to protect pump from frost and freezing, 
particularly when located in loft position.

Pump Location
If possible site the pump in a location where in the unlikely event of a 
water leak, any spillage is contained or routed to avoid electrics or 
areas sensitive to water damage.

1. No routine maintenance is required, but provision should be made 

for easy access to the pump to allow repairs due to normal wear and
tear.

2. Disconnect electrical supply before working on pump.

3.

Turn off water supplies to the pump and release pressure by opening water outlets 
before attempting maintenance.

4.

When the installation is fitted with inline strainers (not supplied with kit), these may 
require periodical cleaning.   The frequency of this operation is dependent upon 
installation conditions.
The strainer is located in the inlet pipework to the pump (see pump connection 
section).  The gauze filter is removed as follows:-
a)

Isolate pump electrically.

b)

Release all system pressure.

c)

Isolate water supply.

d)

Remove screwed hexagonal plug from strainer body (see pump connection 
section).

e)

Remove and clean stainless steel gauze filter.

f)

Re-assemble gauze and secure plug tightly.

g)

After maintenance is completed, refer to commissioning section for instructions 
on re-starting pump.

5.

As water is heated scale deposits are released in areas of hard water (usually south 
of a line between the Wash and Bristol Channel), scale can cause the mechanical 
seal to stick if left without use for long periods.  We recommend the pump is run for at
least 5 minutes every four weeks to “exercise” all working parts.  Run on cool water.  
See technical specification for note on water temperature.  This particularly applies to 
guest bathrooms used infrequently.

Cont....

Содержание Showermate 1.5 bar Single

Страница 1: ...esigned for pressure boosting applications in vented stored water systems inlet pressures to the pump and ambient temperatures must not exceed the values given in the technical specifications This pum...

Страница 2: ...umps are not suitable for boosting a single side of a dual flow mixer valve or tap Consult Stuart Turner for alternative pump Item 1 Service valves not supplied Item 2 Inline suction strainers not sup...

Страница 3: ...alled in a positive head position a gravity flow of approx 0 8 litres per minute is required from the highest outlet to operate the built in flow switch This is normally achieved with a static head of...

Страница 4: ...problem 1 A U bend or downward loop in the supply pipe to the pump of 350 mm depth before rising to the pump should ensure the cylinder vents its air up the expansion pipe not up the pump feed Fig 7 f...

Страница 5: ...of 65 C A 6 minute shower using 10 litres min will consume 40 litres of hot water and 20 litres of cold This means the total quantity of water used from the cold water storage tank will be 60 litres...

Страница 6: ...and system outlet This should run as far as possible in 22 mm copper tube Pipework should only be reduced to 15 mm copper at pump and if necessary when entering the terminal fittings By this method th...

Страница 7: ...sleeve The internal bore of the plastic pipe must be supported against collapse with the pipe manufacturers recommended support sleeve pipe insert c Appropriate plumbing fittings from the John Guest...

Страница 8: ...ctly fitted 5 To release the joint push pipe firmly into the fitting hold the collet down and gently remove pipe If the system has been filled with water care should be taken to isolate the pump and t...

Страница 9: ...n 30 as they may become damaged transmit noise or leak 22 mm Outlet Pipework to shower bathroom 22 x 15 mm Reducer 15 mm Isolating valve to allow easy pump service Not supplied Flow Switch Control Pum...

Страница 10: ...anently connected to the fixed wiring of the mains supply Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules A suitable method of connection would be...

Страница 11: ...oloured brown must be connected to the terminal which is marked with the letter L or coloured red Wiring Diagrams The supply cord and internal wiring within the terminal box are routed and secured to...

Страница 12: ...Ltd or one of their approved repairers On disassembly note the cord retention and routing system Re assemble to the same pattern For information on cable connection consult the wiring diagram and cabl...

Страница 13: ...ure any contaminants chemical residues and foreign bodies are removed from elsewhere in the system 2 Water Supply Always ensure that water storage capacity is adequate to meet the demand Ensure the pu...

Страница 14: ...to the pump and release pressure by opening water outlets before attempting maintenance 4 When the installation is fitted with inline strainers not supplied with kit these may require periodical clean...

Страница 15: ...g the pump must be considered Acid based descalents and aggressive cleaning agents must not come into contact with the pump The pump must be removed from the system prior to the use of these products...

Страница 16: ...del 1 5 bar Single 1 5 bar Twin 2 0 bar Twin Electrical Power supply Volts phase frequency Enclosure Type of motor Power consumption Full load current Rating Max No Starts per hour 230 1 50 IPX4 Induc...

Страница 17: ...hermotrip to auto reset and check duty point and run time is within specification see technical specification No hot water Air locked water feed Boiler is switched off All hot water has been used Faul...

Страница 18: ...of of purchase should accompany the returned unit to avoid delay in action Please record here for your records Always flush system prior to starting a new or serviced pump Always ensure both sides of...

Страница 19: ...19 NOTES...

Страница 20: ...09 2006 95 EC BS EN 60335 1 BS EN 60335 2 41 EN 50366 89 336 EEC BS EN 55014 1 BS EN 55014 2 BS EN 55022 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5...

Страница 21: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...

Отзывы: