Stuart Turner Showermate 1.5 bar Single Скачать руководство пользователя страница 1

Installation Instructions
For Showermate Shower
Booster Pumps

1.5 bar Single, 1.5 bar Twin, 2.0 bar Twin

INDEX

. . . . . . . . . . . . . . . . . . . . . . Page No

Product Description  . . . . . . . . . . . . . . . . 1

Application  . . . . . . . . . . . . . . . . . . . . . . . 1

Storage   . . . . . . . . . . . . . . . . . . . . . . . . . 1

Typical Installation  . . . . . . . . . . . . . . . . . 2

Pump Location  . . . . . . . . . . . . . . . . . . . . 3

Pipework . . . . . . . . . . . . . . . . . . . . . . . . . 5

Pump Connections  . . . . . . . . . . . . . . . . . 6

INDEX

. . . . . . . . . . . . . . . . . . . . . . Page No

Electrical Installation . . . . . . . . . . . . . . . . 10

Commissioning  . . . . . . . . . . . . . . . . . . . . 13

Maintenance  . . . . . . . . . . . . . . . . . . . . . . 14

Technical Specification  . . . . . . . . . . . . . . 16

Noise  . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Trouble Shooting Guide  . . . . . . . . . . . . . 17

Environment Protection   . . . . . . . . . . . . . 17

Please leave this instruction booklet with the pump as it

contains maintenance and safety information.

PRODUCT DESCRIPTION

Electric motor driven single or double-sided peripheral pump complete with an

automatic control system, consisting of flow switches and electronic controls.

APPLICATION

Showermate pumps are designed for pressure boosting applications in vented stored

water systems, inlet pressures to the pump and ambient temperatures must not exceed
the values given in the technical specifications.

This pump set must not be used for any other application without the 
written consent of Stuart Turner Limited and in particular must not be 
connected directly to the mains water supply.

This appliance is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the
appliance.

STORAGE

If this pump is not to be installed immediately on receipt, ensure that it is stored in a dry,

frost and vibration free location in its original packaging.

Содержание Showermate 1.5 bar Single

Страница 1: ...esigned for pressure boosting applications in vented stored water systems inlet pressures to the pump and ambient temperatures must not exceed the values given in the technical specifications This pum...

Страница 2: ...umps are not suitable for boosting a single side of a dual flow mixer valve or tap Consult Stuart Turner for alternative pump Item 1 Service valves not supplied Item 2 Inline suction strainers not sup...

Страница 3: ...alled in a positive head position a gravity flow of approx 0 8 litres per minute is required from the highest outlet to operate the built in flow switch This is normally achieved with a static head of...

Страница 4: ...problem 1 A U bend or downward loop in the supply pipe to the pump of 350 mm depth before rising to the pump should ensure the cylinder vents its air up the expansion pipe not up the pump feed Fig 7 f...

Страница 5: ...of 65 C A 6 minute shower using 10 litres min will consume 40 litres of hot water and 20 litres of cold This means the total quantity of water used from the cold water storage tank will be 60 litres...

Страница 6: ...and system outlet This should run as far as possible in 22 mm copper tube Pipework should only be reduced to 15 mm copper at pump and if necessary when entering the terminal fittings By this method th...

Страница 7: ...sleeve The internal bore of the plastic pipe must be supported against collapse with the pipe manufacturers recommended support sleeve pipe insert c Appropriate plumbing fittings from the John Guest...

Страница 8: ...ctly fitted 5 To release the joint push pipe firmly into the fitting hold the collet down and gently remove pipe If the system has been filled with water care should be taken to isolate the pump and t...

Страница 9: ...n 30 as they may become damaged transmit noise or leak 22 mm Outlet Pipework to shower bathroom 22 x 15 mm Reducer 15 mm Isolating valve to allow easy pump service Not supplied Flow Switch Control Pum...

Страница 10: ...anently connected to the fixed wiring of the mains supply Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules A suitable method of connection would be...

Страница 11: ...oloured brown must be connected to the terminal which is marked with the letter L or coloured red Wiring Diagrams The supply cord and internal wiring within the terminal box are routed and secured to...

Страница 12: ...Ltd or one of their approved repairers On disassembly note the cord retention and routing system Re assemble to the same pattern For information on cable connection consult the wiring diagram and cabl...

Страница 13: ...ure any contaminants chemical residues and foreign bodies are removed from elsewhere in the system 2 Water Supply Always ensure that water storage capacity is adequate to meet the demand Ensure the pu...

Страница 14: ...to the pump and release pressure by opening water outlets before attempting maintenance 4 When the installation is fitted with inline strainers not supplied with kit these may require periodical clean...

Страница 15: ...g the pump must be considered Acid based descalents and aggressive cleaning agents must not come into contact with the pump The pump must be removed from the system prior to the use of these products...

Страница 16: ...del 1 5 bar Single 1 5 bar Twin 2 0 bar Twin Electrical Power supply Volts phase frequency Enclosure Type of motor Power consumption Full load current Rating Max No Starts per hour 230 1 50 IPX4 Induc...

Страница 17: ...hermotrip to auto reset and check duty point and run time is within specification see technical specification No hot water Air locked water feed Boiler is switched off All hot water has been used Faul...

Страница 18: ...of of purchase should accompany the returned unit to avoid delay in action Please record here for your records Always flush system prior to starting a new or serviced pump Always ensure both sides of...

Страница 19: ...19 NOTES...

Страница 20: ...09 2006 95 EC BS EN 60335 1 BS EN 60335 2 41 EN 50366 89 336 EEC BS EN 55014 1 BS EN 55014 2 BS EN 55022 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5...

Страница 21: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...

Отзывы: