- 13 -
Cont...
4 ELECTRICAL INSTALLATION
4.1
Regulations:
The electrical installation must be carried out in accordance with the
current national electrical regulations and installed by a qualified person.
4.2 Before starting work on the electrical supply ensure power supply is isolated.
4.3
DO NOT
allow the supply cord to contact hot surfaces
4.4
DO NOT
switch the power on until the unit has been filled with water and has been
earthed.
4.5
Safety:
The mains supply to the unit must be connected through the 40 Amp RCD
(fitted).
4.6
Electrical supply:
The main incoming electrical supply to the property should be of
adequate voltage, current and temperature rating for the requirements of the
Electrastream as well as all other electrical requirements within the property. It is
advised to turn the switch off when hot water and heating are not required i.e. holidays
etc.
4.7
Off – peak electrical supply:
To achieve the most efficient performance from the
Electrastream it is strongly recommended to use an ‘Economy 18’ Off-Peak electrical
supply. Other off-peak options such as ‘Economy 7’ or ‘Economy 10’ tariffs are also
available from most UK electrical suppliers.
Consult the local electricity suppliers to determine what economy tariff options are
available before installing the Electrastream.
4.8
Typical power supply:
Figure 8 shows a typical power supply for economy meters.
Consult electricity supply company for specific requirements.
Fig. 8 Typical power supply