21
START-UP AND OPERATION, CONTINUED: LOAD LIMITS
21
PRODUCT PLACEMENT / HONEYCOMB AIRFLOW CONSIDERATION / LOAD LINES
3. Load Lines
Load lines limit where product can be placed
and/or stacked in case.
Do not allow product to break load line between
honeycomb air diffuser and return air grille.
Do not stack product nearer than 1” to underside
of honeycomb air diffuser.
Do not stack product nearer than 1” to underside
of shelves.
Do not stack product nearer than 1” from rear
plenum.
Do not stack product on return air grille.
Do not allow product to hang over front of
shelves.
Do not allow product on decks to hang over
product stop.
See illustration below.
1. Product Placement
Product can be placed on decking or steps
(risers) within self-service display area.
A wide range of product may be displayed.
2. Honeycomb Airflow Consideration
Airflow from honeycomb air diffuser is designed
to flow over (and around) product to return air
grille at case front.
Caution! You must keep the honeycomb air
diffuser unblocked by product for airflow to reach
return air grille.
Caution! You must ALSO keep product OFF
return air grill at case front (as illustrated below).
Honeycomb
Air Diffuser
5”
Angled View Of
Return Air Grille
Side View of
Merchandiser
Acrylic Air
Deflector
Load Line
1” Min. From
Rear Perforated
Plenum
1” Min. From Rear
Perforated Plenum
1” Min.
Load Line
1” Min.
Load Line
Product
Stop
Sample
Product
Sample Product
(Typ.)
Load Line At
Front Of
Shelves (Typ.)
Top
Plenum
Load Line 1” Min.
Below Honeycomb
Air Diffuser
Caution!
Return Air Grille
Must Not Be
Blocked By
Product!