17
CASE DESIGN, CONT’D: TUB AREA (AFTER DECK PAN REMOVAL)
5. Tub Area After Deck Pan Removal
Note:
Refrigeration service to be accomplished by refrigeration / electrical contractors only.
Caution! Turn main power off before accessing tub area.
Illustration below shown after removal of deck pans.
After cleaning or servicing in tub area, return deck pans to case and return power to case.
Refrigeration
Line Route
--- Case Rear ---
--- Case Front ---
Drain
Evaporator Coil
Cover
TXV
Evaporator Fans
Refrigeration
Lines
Evaporator
Coil
Acrylic Return
Airflow Deflector
Air Discharge