18
CASE DESIGN, CONT’D: LED LIGHT SWITCH LOCATIONS / LED LIGHTS / THERMOMETER
6. LED Light Switch Locations
Cases with rear sliding doors have light switch
in column cover (for easy access at case rear).
Cases with solid back rear plenums have light
switch in header.
See illustrations below.
7. LED Lights
LED lights are located at both header and
shelving of case (as shown below).
Check that ALL of the light plugs are properly
connected to the LED light.
Plug must be inserted ALL THE WAY into the
LED light orifice (with no gap) to work properly.
See
TROUBLESHOOTING
section in manual
if LED lights malfunction.
LED Light (At
Underside Of Header)
LED Lights
(At Underside
Of Shelves)
Light Switch
Thermometer
8. Thermometer Function & Placement
Cases with lower rear sliding doors have
different thermometer location than units with solid
back rear lower plenums (as shown in
illustrations below).
Thermometer provides temperature of
refrigerated section of case.
Thermometers reflect warmest air temperature in
merchandiser. They do not provide actual food
temperature.
Use probe thermometers to determine actual
product temperatures.
--- Case With Solid Back Rear Plenum ---
--- Case With Rear Sliding Doors ---
LED Light
Plug