7
START-UP AND OPERATION: LIGHTS [STANDARD vs. LED LIGHTS]
Start-Up And Operation
Warning! Disconnect power before providing
maintenance and service to unit.
Caution: Lamps have been treated to resist breakage
and must be replaced with similarly treated lamps.
Note: Warranty will be void if claims arise from
negligence, misuse of goods, extreme environmental
conditions or improper maintenance. See Overview
And Warnings section in this operating manual.
1. Standard Fluorescent Style Light Fixtures
Removal of lamp:
Rotate lamp (1/4-turn) either direction to disengage
(upper or lower) pins/contacts from lamp-mounting
sockets.
Remove bulb by applying even pressure from back
side at the bulb ends and pulling the remaining
contact from sockets.
See illustrations at top-right.
Installation of lamp:
Align pins with slot.
Insert pins into socket by rotating the bulb 1/4-turn to
secure either the (upper or lower) pin contacts into the
sockets.
Rotate remaining bulb contacts (1/4-turn) into
remaining lamp mounting socket contacts.
See illustrations at top-right.
2. LED Style Light Fixtures
Removal of lamp:
If case is provided with LED lights, they will rarely
require change-out.
Contact Structural Concepts’ Technical Service
Department for replacement parts (see the Technical
Service section of operating manual).
Replacement of lamp:
To replace LED Light Fixture, simply disconnect the
existing LED light from its brackets and/or
self-adhesive tape. Replace.
Note: LED Light and Plug must be connected in a
specific manner or they will not work.
Make certain flat edge of plug connects to flat edge
of LED light.
See illustrations at right.
LED’s Oval Form
Plug’s
Oval Form
--- LED Plug & Light Fixture ---
Retaining
Springs