Setting the looper (Fig. 4, Fig. 7 and Fig. 8)
In the moment of the loop take-up the looper fingers should be placed
0.1 - 0.2 mm above the needle, also when a thicker needle is used. The needle should
not be touched!
The horizontal distance from the large looper finger to the needle eye should be
1.5 +0.5 mm (Fig. 7). On the left side, when the loop is released, the needle should
move centrically through the looper fingers. These values can be set through turning
and moving eccentric bolt (1) (release adjusting screw (2)), and through turning the
looper shaft against connecting the fork (5) (Fig. 4).
Check the looper movement through carefully moving the main shaft by means of the
handwheel.
Check if all fastening screws are tight!