18
MA_VEB100-6_A2_200716_en.doc
3.4
Looper
3.4.1
Removing and remounting the looper (Fig. 4)
A T T E N T I O N !
Switch off machine electrically.
Release cap screw (1) and pull the looper towards the front.
When remounting the looper make sure that it is completely pushed in and that its
positioning surface fits exactly to the looper take-up.
Tighten cap screw (1).
3.4.2
Removing and remounting the looper shaft (Fig. 4)
The looper shaft with ball jointed lever (12) can be taken out after removing the
looper and releasing set collars (6) and (11).
3.4.3
Looper deflection (Fig. 6)
The looper deflection is 18 +0.5 mm (control dimension).