34
MA_VEB200-1-2_A2_181015_en
At least one cycle needs to be sewn so that the setting is saved before the
machine is switched off.
For class VEB200-1, -1F, -2, -2F:
position 1
position 2
P1E
280
P2E
150
P1A
305
P2A
175
For class VEB200-1RF, -2RF:
position 1
position 2
P1E
275
P2E
150
P1A
300
P2A
175
Depending on the looper and needle setting, the values could variate slightly.
3.13
Display of the needle positions
Function
Parameter
Display of the Positions 1 and 2 (down / up)
F-172
The setting of the positions can be easily checked using this function.
After entering the code number “1907” and button “E” for the technician
level:
-
Select parameter F-172.
Display shows: .1.7.2.
-
Press “E” button.
Sr 3
-
Turn handwheel according to the motor's direction of rotation.
Display on the control:
Segment 5 is switched on
⇒
Position 1E
Segment 5 is switched off
⇒
Position 1A
Segment 6 is switched on
⇒
Position 2E
Segment 6 is switched off
⇒
Position 2A
-
Press “P” button.
.1.7.2.
-
Press “P” button.